On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)

被引:0
|
作者
Bak, Jino [1 ]
Jeong, Kyoungkeun [2 ]
Keum, Ki Chang [2 ]
Park, Suk Won [1 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2006年 / 24卷 / 04期
关键词
IGRT; CBCT; Set-up error;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. Materials and Methods: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). Resutts: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, |n the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. Conclusion: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the an-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.
引用
收藏
页码:294 / 299
页数:6
相关论文
共 50 条
  • [21] Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy
    Zhen, Xin
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 7979 - 7993
  • [22] Image Guided Radiotherapy (IGRT) for Nasopharyngeal Cancer with Megavoltage Cone-beam CT (MV-CBCT)
    Wang, X.
    Li, L.
    Hu, C.
    Xu, Z.
    Feng, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S605 - S605
  • [23] Feasibility study of cone-beam computed tomography (CBCT) reconstruction algorithm for proton image-guided radiation therapy (IGRT)
    Han, Dong-Kyoon
    Jo, Byungdu
    Lee, Min-Hee
    Yoo, Myung Seok
    Kim, Kyuseok
    Lee, Youngjin
    [J]. OPTIK, 2016, 127 (20): : 9691 - 9694
  • [24] Image Guided Stereotactic Body Radiotherapy for Lung Cancer Using 4D Treatment Planning and On-line Cone-beam CT
    Wong, T. P.
    Rao, M.
    Cao, D.
    Ye, J.
    Shepard, D.
    Mehta, V.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S690 - S690
  • [25] Vector analysis of patient setup with image guided radiation therapy (IGRT) via Kv cone beam CT (CBCT)
    Perks, J. R.
    Jennelle, R. L. S.
    Chen, A.
    Franklin, S.
    Liu, T.
    Palo, B.
    Purdy, J. A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S641 - S641
  • [26] Exact image reconstruction in reverse helical cone-beam CT for radiation therapy
    Cho, S.
    Xia, D.
    Pelizzari, C.
    Pan, X.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2633 - 2634
  • [27] Dose-guided radiation therapy using low-dose megavoltage Cone-Beam CT
    Pouliot, J
    Xia, P
    Aubin, M
    Verhey, L
    Langen, K
    Bani-Hashemi, A
    Svatos, M
    Ghelmansarai, F
    Mitchke, M
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1337 - 1338
  • [28] Image guided radiation therapy using cone-beam computed tomography in stereotactic radiosurgery for lung tumor
    Song, S.
    Choi, E.
    Lee, J.
    Kim, W.
    Park, S.
    Shin, S.
    Lee, S.
    Ahn, S.
    Kim, J.
    Park, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S482 - S482
  • [29] Dose calculation with a cone beam CT image in image-guided radiation therapy
    Usui K.
    Ichimaru Y.
    Okumura Y.
    Murakami K.
    Seo M.
    Kunieda E.
    Ogawa K.
    [J]. Radiological Physics and Technology, 2013, 6 (1) : 107 - 114
  • [30] Scatter Correction for Cone-Beam CT in Radiation Therapy
    Zhu, L.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)