Accuracy of stereotactic ultrasound (BAT®) for prostate repositioning-A 3D on-line fiducial based assessment with cone-beam CT

被引:0
|
作者
Boda-Heggemann, J. [1 ]
Koehler, F. [1 ]
Wertz, H. [1 ]
Mennemeyer, P. [1 ]
Loeb, I. [1 ]
Mai, S. [1 ]
Hesser, J. [1 ]
Lohr, F. [1 ]
Wenz, F. [1 ]
机构
[1] Univ Klinikum Mannheim, Mannheim, Germany
关键词
D O I
10.1016/j.ijrobp.2007.07.2132
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2946
引用
收藏
页码:S731 / S731
页数:1
相关论文
共 50 条
  • [1] Accuracy of ultrasound-based (BAT) prostate-repositioning:: A three-dimensional on-line fiducial-based assessment with cone-beam computed tomography
    Boda-Heggemann, Judit
    Koehler, Frederick Marc
    Koepper, Beate
    Wolff, Dirk
    Wertz, Hansjoerg
    Mai, Sabine
    Hesser, Jorgen
    Lohr, Frank
    Wenz, Frederik
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1247 - 1255
  • [2] Accuracy of stereotactic ultrasound (BAT) for daily repositioning in upper abdomen - An online comparison by 3D-3D matching with cone-beam CT
    Boda-Heggemann, J.
    Mennemeyer, P.
    Wertz, H.
    Ehmann, M.
    Hermann, B.
    Koehler, F. M.
    Riesenacker, N.
    Lohr, F.
    Wenz, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S542 - S542
  • [3] Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT
    Boda-Heggemann, Judit
    Koehler, Frederick Marc
    Wertz, Hansjoerg
    Ehmann, Michael
    Hermann, Brigitte
    Riesenacker, Nadja
    Kuepper, Beate
    Lohr, Frank
    Wenz, Frederik
    [J]. RADIATION ONCOLOGY, 2008, 3 (1)
  • [4] Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT
    Judit Boda-Heggemann
    Frederick Marc Köhler
    Hansjörg Wertz
    Michael Ehmann
    Brigitte Hermann
    Nadja Riesenacker
    Beate Küpper
    Frank Lohr
    Frederik Wenz
    [J]. Radiation Oncology, 3
  • [5] On-line corrections using a cone-beam CT for extracranial stereotactic treatments
    Casamassima, F.
    Masi, L.
    Polli, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S226 - S226
  • [6] Repositioning accuracy of two different mask systems - 3D revisited: Comparison using true 3D/3D matching with cone-beam CT
    Boda-Heggemann, Judit
    Walter, Cornelia
    Rahn, Angelika
    Wertz, Hansjoerg
    Loeb, Iris
    Lohr, Frank
    Wenz, Frederik
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05): : 1568 - 1575
  • [7] Quality rating of the stereotactic ultrasound for prostate positioning - online comparison with 3D imaging with cone beam CT
    Kohler, F.
    Boda-Heggemann, J.
    Wertz, H.
    Mennemayer, P.
    Mai, S.
    Lob, I
    Wenz, F.
    Lohr, E.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 16 - 16
  • [8] Repositioning accuracy of two different mask systems:: A comparison by true 3D-3D matching with cone-beam CT
    Boda-Heggemann, J.
    Walter, C.
    Wertz, H.
    Kupper, B.
    Loeb, I.
    Rahn, A.
    Lohr, F.
    Wenz, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S242 - S242
  • [9] Prostate localization: Fiducial marker versus cone beam CT (CBCT) 3D image fusion
    Hammoud, R. W.
    Pradhan, D.
    Kim, J.
    Patel, S. H.
    Kowalski, S.
    Guan, H.
    Xu, Y.
    Elshaikh, M.
    Ajlouni, M.
    Movsas, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S679 - S680
  • [10] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. SENSORS, 2022, 22 (03)