Repositioning accuracy of two different mask systems - 3D revisited: Comparison using true 3D/3D matching with cone-beam CT

被引:76
|
作者
Boda-Heggemann, Judit [1 ]
Walter, Cornelia [1 ]
Rahn, Angelika [1 ]
Wertz, Hansjoerg [1 ]
Loeb, Iris [1 ]
Lohr, Frank [1 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Mannheim Med Ctr, Dept Radiat Oncol, D-68167 Mannheim, Germany
关键词
reproducibility; positioning; head mask; cone-beam CT; frameless stereotaxy;
D O I
10.1016/j.ijrobp.2006.08.054
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The repositioning accuracy of mask-based fixation systems has been assessed with two-dimensional/two-dimensional or two-dimensional/three-dimensional (3D) matching. We analyzed the accuracy of commercially available head mask systems, using true 3D/3D matching, with X-ray volume imaging and cone-beam CT. Methods and Materials: Twenty-one patients receiving radiotherapy (intracranial/head-and-neck tumors) were evaluated (14 patients with rigid and 7 with thermoplastic masks). X-ray volume imaging was analyzed online and offline separately for the skull and neck regions. Translation/rotation errors of the target isocenter were analyzed. Four patients were treated to neck sites. For these patients, repositioning was aided by additional body tattoos. A separate analysis of the setup error on the basis of the registration of the cervical vertebra was performed. The residual error after correction and intrafractional motility were calculated. Results: The mean length of the displacement vector for rigid masks was 0.312 +/- 0.152 cm (intracranial) and 0.586 +/- 0.294 cm (neck). For the thermoplastic masks, the value was 0.472 +/- 0.174 cm (intracranial) and 0.726 +/- 0.445 cm (neck). Rigid masks with body tattoos had a displacement vector length in the neck region of 0.35 +/- 0.197 cm. The intracranial residual error and intrafractional motility after X-ray volume imaging correction for rigid masks was 0.188 +/- 0.074 cm, and was 0.134 +/- 0.14 cm for thermoplastic masks. Conclusions: The results of our study have demonstrated that rigid masks have a high intracranial repositioning accuracy per se. Given the small residual error and intrafractional movement, thermoplastic masks may also be used for high-precision treatments when combined with cone-beam CT. The neck region repositioning accuracy was worse than the intracranial accuracy in both cases. However, body tattoos and image guidance improved the accuracy. Finally, the combination of both mask systems with 3D image guidance has the potential to replace therapy simulation and intracranial stereotaxy. (c) 2006 Elsevier Inc.
引用
收藏
页码:1568 / 1575
页数:8
相关论文
共 50 条
  • [1] Comparison of repositioning accuracy of two different mask systems using true 3D-3D matching with cone-beam CT
    Boda-Heggemann, J.
    Walter, C.
    Wertz, H.
    Kuepper, B.
    Rahn, A.
    Lohr, F.
    Wenz, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 119 - 120
  • [2] Repositioning accuracy of two different mask systems:: A comparison by true 3D-3D matching with cone-beam CT
    Boda-Heggemann, J.
    Walter, C.
    Wertz, H.
    Kupper, B.
    Loeb, I.
    Rahn, A.
    Lohr, F.
    Wenz, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S242 - S242
  • [3] 3D cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02): : 329 - 347
  • [4] Cone-beam convolution 3D reconstruction
    Yang, H
    Sun, HY
    Wang, C
    [J]. ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7925 - 7927
  • [5] Cascaded systems analysis of the 3D NEQ for cone-beam CT and tomosynthesis
    Tward, D. J.
    Siewerdsen, J. H.
    Fahrig, R. A.
    Pineda, A. R.
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [6] Cascaded Systems Analysis of the 3D NEQ of Cone-Beam CT: Investigation of Voxel Size in Relation to 3D Noise Aliasing
    Tward, D.
    Richard, S.
    Siewerdsen, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [7] 3D Analytic Cone-Beam Reconstruction for Multiaxial CT Acquisitions
    Yin, Zhye
    De Man, Bruno
    Pack, Jed
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2009, 2009
  • [8] DEVELOPMENT OF A 3D CT SCANNER WITH A CONE-BEAM AND VIDEOFLUOROSCOPIC SYSTEM
    ENDO, M
    SATOH, K
    OKAZAKI, T
    HATTORI, Y
    KOBAYASHI, S
    JIMBO, M
    [J]. RADIOLOGY, 1995, 197 : 292 - 292
  • [9] 3D tumor measurement in cone-beam CT breast imaging
    Chen, ZK
    Ning, R
    [J]. MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 558 - 569
  • [10] Study on reconstructed image of 3D cone-beam CT scanner
    Nakamori, N
    Sudou, T
    Kanamori, H
    Endou, M
    Kusakabe, M
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 696 - 705