Short-term reproducibility of the 24-h ambulatory monitoring of brachial and central hemodynamics in untreated Chinese

被引:4
|
作者
Wang, Ying [1 ,2 ]
Zhang, Dong-Yan [1 ,2 ]
Guo, Qian-Hui [1 ,2 ]
Cheng, Yi-Bang [1 ,2 ]
Huang, Qi-Fang [1 ,2 ]
Sheng, Chang-Sheng [1 ,2 ]
Xu, Ting-Yan [1 ,2 ]
Wang, Ji-Guang [1 ,2 ]
Li, Yan [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Ctr Epidemiol Studies & Clin Trials, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Key Lab Hypertens, Ctr Vasc Evaluat,Shanghai Inst Hypertens,Sch Med, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Ambulatory blood pressure monitoring; central blood pressure; pulse wave velocity; augmentation index; reproducibility; BLOOD-PRESSURE-MEASUREMENTS; ARTERIAL STIFFNESS INDEX; HEART-RATE-VARIABILITY; PULSE-WAVE VELOCITY; OSCILLOMETRIC ESTIMATION; PRACTICE GUIDELINES; EUROPEAN-SOCIETY; HYPERTENSION; VALIDATION; MANAGEMENT;
D O I
10.1080/08037051.2019.1612707
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Advanced technology allows non-invasive monitoring of the 24-h brachial and central hemodynamics simultaneously. However, related reproducibility data was limited in White patients. We therefore explored if the novel measurements would be reproducible in Chinese.Methods: From February 2017 to January 2018, 152 untreated patients who were suspected of hypertension and referred for ambulatory blood pressure (BP) monitoring were recruited. Ambulatory BP monitoring was repeated within one month (median, 12.5 days) using the Mobil-O-Graph monitors (IEM, Germany). Reproducibility was assessed as the intra-class correlation coefficient (ICC), coefficient of variation (CV), and repeatability coefficient (RC).Results: The 152 participants (average age, 58.6 years) included 54 men and 98 women. The first and second means of the ambulatory brachial and central BPs, pulse wave velocity (PWV), augmentation pressure, augmentation index (AIx) and AIx at a heart rate of 75 beats per minute (AIx@75) were all similar (p >= 0.065), except that the repeated daytime and 24-h brachial and central systolic BPs and pulse pressure slightly differed by approximately 1-2mmHg (p <= 0.011). ICC ranged from 0.70 to 0.94 for all ambulatory BPs and >= 0.91 for the arterial measurements. CV was in the range from 5.0% to 10.3% for all BPs and PWV measurements, and from 15.5% to 22.3% for AIx and AIx@75. RC expressed as percentages of maximal variation was <15% for the PWVs and ranged from 25.5% to 54.7% for BPs, AIx and AIx@75.Conclusions: The 24-h ambulatory brachial and central BPs and arterial measurements were reproducible within a short time period in Chinese, and could therefore be used in clinical practice and research settings.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [41] IS 24-H AMBULATORY ESOPHAGEAL PH MONITORING USEFUL IN A DISTRICT GENERAL-HOSPITAL
    DONALD, IP
    FORD, GA
    WILKINSON, SP
    LANCET, 1987, 1 (8524): : 89 - 92
  • [42] Evaluation of short-term and long-term results after laparoscopic antireflux surgery: esophageal manometry and 24-h pH monitoring versus quality of life index
    Blazejczyk, Katarzyna
    Hoene, Andreas
    Glitsch, Anne
    Busemann, Alexandra
    Heidecke, Claus Dieter
    Patrzyk, Maciej
    LANGENBECKS ARCHIVES OF SURGERY, 2013, 398 (08) : 1107 - 1114
  • [43] Evaluation of short-term and long-term results after laparoscopic antireflux surgery: esophageal manometry and 24-h pH monitoring versus quality of life index
    Katarzyna Blazejczyk
    Andreas Hoene
    Anne Glitsch
    Alexandra Busemann
    Claus Dieter Heidecke
    Maciej Patrzyk
    Langenbeck's Archives of Surgery, 2013, 398 : 1107 - 1114
  • [44] 24-h ambulatory blood pressure variability and hypertensive nephropathy in Han Chinese hypertensive patients
    Hung, Ming-Hui
    Huang, Chin-Chou
    Chung, Chia-Min
    Chen, Jaw-Wen
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (02): : 281 - 288
  • [45] Accuracy of pulse rate derived from 24-h ambulatory blood pressure monitoring compared with heart rate from 24-h Holter-ECG
    Lauder, Lucas
    Scholz, Sean S.
    Ewen, Sebastian
    Lettner, Christine
    Ukena, Christian
    Bohm, Michael
    Mahfoud, Felix
    JOURNAL OF HYPERTENSION, 2020, 38 (12) : 2387 - 2392
  • [46] 24-h ambulatory pulse wave velocity and central blood pressure in type 2 diabetes
    Krogager C.
    Rossen N.B.
    Laugesen E.
    Knudsen S.T.
    Poulsen P.L.
    Hansen K.W.
    Artery Research, 2014, 8 (3) : 73 - 79
  • [47] Variation in paediatric 24-h ambulatory blood pressure monitoring interpretation by Canadian and UK physicians
    Isabella Z. Stefanova
    Manish D. Sinha
    Douglas J. Stewart
    Abdulaziz Bamhraz
    Anne Fournier
    Kevin C. Harris
    Guido Filler
    Damien Noone
    Chia Wei Teoh
    Janis Dionne
    Rahul Chanchlani
    Journal of Human Hypertension, 2023, 37 : 363 - 369
  • [48] Variation in paediatric 24-h ambulatory blood pressure monitoring interpretation by Canadian and UK physicians
    Stefanova, Isabella Z.
    Sinha, Manish D.
    Stewart, Douglas J.
    Bamhraz, Abdulaziz
    Fournier, Anne
    Harris, Kevin C.
    Filler, Guido
    Noone, Damien
    Teoh, Chia Wei
    Dionne, Janis
    Chanchlani, Rahul
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (05) : 363 - 369
  • [49] INFLUENCE OF MONITORING PROCEDURE ON 24-H AMBULATORY BLOOD-PRESSURE TRACINGS - A NONINVASIVE STUDY
    ANTIVALLE, M
    LATTUADA, S
    SALVAGGIO, A
    GRILLO, A
    RINDI, M
    LIBRETTI, A
    JOURNAL OF HYPERTENSION, 1989, 7 : S352 - S352
  • [50] CHRONIC HOARSENESS SECONDARY TO GASTROESOPHAGEAL REFLUX DISEASE - DOCUMENTATION WITH 24-H AMBULATORY PH MONITORING
    WIENER, GJ
    KOUFMAN, JA
    WU, WC
    COOPER, JB
    RICHTER, JE
    CASTELL, DO
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1989, 84 (12): : 1503 - 1508