Short-term reproducibility of the 24-h ambulatory monitoring of brachial and central hemodynamics in untreated Chinese

被引:4
|
作者
Wang, Ying [1 ,2 ]
Zhang, Dong-Yan [1 ,2 ]
Guo, Qian-Hui [1 ,2 ]
Cheng, Yi-Bang [1 ,2 ]
Huang, Qi-Fang [1 ,2 ]
Sheng, Chang-Sheng [1 ,2 ]
Xu, Ting-Yan [1 ,2 ]
Wang, Ji-Guang [1 ,2 ]
Li, Yan [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Ctr Epidemiol Studies & Clin Trials, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Key Lab Hypertens, Ctr Vasc Evaluat,Shanghai Inst Hypertens,Sch Med, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Ambulatory blood pressure monitoring; central blood pressure; pulse wave velocity; augmentation index; reproducibility; BLOOD-PRESSURE-MEASUREMENTS; ARTERIAL STIFFNESS INDEX; HEART-RATE-VARIABILITY; PULSE-WAVE VELOCITY; OSCILLOMETRIC ESTIMATION; PRACTICE GUIDELINES; EUROPEAN-SOCIETY; HYPERTENSION; VALIDATION; MANAGEMENT;
D O I
10.1080/08037051.2019.1612707
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Advanced technology allows non-invasive monitoring of the 24-h brachial and central hemodynamics simultaneously. However, related reproducibility data was limited in White patients. We therefore explored if the novel measurements would be reproducible in Chinese.Methods: From February 2017 to January 2018, 152 untreated patients who were suspected of hypertension and referred for ambulatory blood pressure (BP) monitoring were recruited. Ambulatory BP monitoring was repeated within one month (median, 12.5 days) using the Mobil-O-Graph monitors (IEM, Germany). Reproducibility was assessed as the intra-class correlation coefficient (ICC), coefficient of variation (CV), and repeatability coefficient (RC).Results: The 152 participants (average age, 58.6 years) included 54 men and 98 women. The first and second means of the ambulatory brachial and central BPs, pulse wave velocity (PWV), augmentation pressure, augmentation index (AIx) and AIx at a heart rate of 75 beats per minute (AIx@75) were all similar (p >= 0.065), except that the repeated daytime and 24-h brachial and central systolic BPs and pulse pressure slightly differed by approximately 1-2mmHg (p <= 0.011). ICC ranged from 0.70 to 0.94 for all ambulatory BPs and >= 0.91 for the arterial measurements. CV was in the range from 5.0% to 10.3% for all BPs and PWV measurements, and from 15.5% to 22.3% for AIx and AIx@75. RC expressed as percentages of maximal variation was <15% for the PWVs and ranged from 25.5% to 54.7% for BPs, AIx and AIx@75.Conclusions: The 24-h ambulatory brachial and central BPs and arterial measurements were reproducible within a short time period in Chinese, and could therefore be used in clinical practice and research settings.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [31] SHORT-TERM VARIABILITY OF 24-H SYSTOLIC BLOOD PRESSURE IS ASSOCIATED WITH MICROALBUMINURIA IN PATIENTS WITH PRIMARY HYPERTENSION
    Mule, G.
    Calcaterra, I.
    Foraci, A. C.
    Castiglia, A.
    Costanzo, M.
    Vario, M. G.
    Cerasola, G.
    Cattone, S.
    JOURNAL OF HYPERTENSION, 2015, 33 : E288 - E288
  • [32] Short-term outcome after ischemic stroke and 24-h blood pressure variability: association and predictors
    Maria Kamieniarz-Mędrygał
    Tomasz Łukomski
    Radosław Kaźmierski
    Hypertension Research, 2021, 44 : 188 - 196
  • [33] Response to: Reproducibility of 24-h ambulatory blood pressure and measures of autonomic function: methodological and statistical issue
    Morrin, Niamh M.
    Stone, Mark R.
    Henderson, Keiran J.
    Gibbon, Karl
    BLOOD PRESSURE MONITORING, 2017, 22 (04) : 244 - 245
  • [34] Should 24-h Ambulatory Blood Pressure Monitoring Be Done in Every Patient With Diabetes?
    Parati, Gianfranco
    Bilo, Grzegorz
    DIABETES CARE, 2009, 32 : S298 - S304
  • [35] Usefulness of 24-h ambulatory blood pressure monitoring in HIV-infected patients
    Nuernberg, M.
    Lang, S.
    Haddour, N.
    Ederhy, S.
    El Asri, C.
    Dufour-Soulat, L.
    Van der Vynckt, C.
    Charbonnier, M.
    Cohen, A.
    Boccara, F.
    ANTIVIRAL THERAPY, 2014, 19 : A40 - A40
  • [36] Analysis of the data obtained at ambulatory 24-h monitoring of arterial pressure in hypertensive subjects
    Leonova, MV
    Belousov, YB
    Semenchuk, GA
    Malysheva, EA
    Upnitsky, AA
    Istratov, SY
    TERAPEVTICHESKII ARKHIV, 1997, 69 (01) : 35 - 38
  • [37] NONINVASIVE, AUTOMATIC 24-H AMBULATORY BLOOD-PRESSURE MONITORING IN NORMOTENSIVE SUBJECTS
    SUNDBERG, S
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1987, 56 (04): : 381 - 383
  • [38] AZILSARTAN MEDOXOMIL PROPORTIONALLY DECREASES CENTRAL AND BRACHIAL 24-H AMBULATORY BLOOD PRESSURE IN DIABETIC PATIENTS WITH DIFFICULT-TO-CONTROL ARTERIAL HYPERTENSION
    Starostina, E.
    Kotovskaya, Y.
    Kobalava, Z.
    JOURNAL OF HYPERTENSION, 2016, 34 : E143 - E143
  • [39] LONG-TERM EEG MONITORING WITH A 24-H CASSETTE RECORDER
    ZETTERLUND, B
    BROMSTER, O
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 49 (3-4): : P79 - P79
  • [40] A prospective study of oesophageal 24-h ambulatory pH monitoring in patients with functional dyspepsia
    Gerson, LB
    Triadafilopoulos, G
    DIGESTIVE AND LIVER DISEASE, 2005, 37 (02) : 87 - 91