共 50 条
Short-term reproducibility of the 24-h ambulatory monitoring of brachial and central hemodynamics in untreated Chinese
被引:4
|作者:
Wang, Ying
[1
,2
]
Zhang, Dong-Yan
[1
,2
]
Guo, Qian-Hui
[1
,2
]
Cheng, Yi-Bang
[1
,2
]
Huang, Qi-Fang
[1
,2
]
Sheng, Chang-Sheng
[1
,2
]
Xu, Ting-Yan
[1
,2
]
Wang, Ji-Guang
[1
,2
]
Li, Yan
[1
,2
]
机构:
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Ctr Epidemiol Studies & Clin Trials, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Key Lab Hypertens, Ctr Vasc Evaluat,Shanghai Inst Hypertens,Sch Med, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Ambulatory blood pressure monitoring;
central blood pressure;
pulse wave velocity;
augmentation index;
reproducibility;
BLOOD-PRESSURE-MEASUREMENTS;
ARTERIAL STIFFNESS INDEX;
HEART-RATE-VARIABILITY;
PULSE-WAVE VELOCITY;
OSCILLOMETRIC ESTIMATION;
PRACTICE GUIDELINES;
EUROPEAN-SOCIETY;
HYPERTENSION;
VALIDATION;
MANAGEMENT;
D O I:
10.1080/08037051.2019.1612707
中图分类号:
R6 [外科学];
学科分类号:
1002 ;
100210 ;
摘要:
Objective: Advanced technology allows non-invasive monitoring of the 24-h brachial and central hemodynamics simultaneously. However, related reproducibility data was limited in White patients. We therefore explored if the novel measurements would be reproducible in Chinese.Methods: From February 2017 to January 2018, 152 untreated patients who were suspected of hypertension and referred for ambulatory blood pressure (BP) monitoring were recruited. Ambulatory BP monitoring was repeated within one month (median, 12.5 days) using the Mobil-O-Graph monitors (IEM, Germany). Reproducibility was assessed as the intra-class correlation coefficient (ICC), coefficient of variation (CV), and repeatability coefficient (RC).Results: The 152 participants (average age, 58.6 years) included 54 men and 98 women. The first and second means of the ambulatory brachial and central BPs, pulse wave velocity (PWV), augmentation pressure, augmentation index (AIx) and AIx at a heart rate of 75 beats per minute (AIx@75) were all similar (p >= 0.065), except that the repeated daytime and 24-h brachial and central systolic BPs and pulse pressure slightly differed by approximately 1-2mmHg (p <= 0.011). ICC ranged from 0.70 to 0.94 for all ambulatory BPs and >= 0.91 for the arterial measurements. CV was in the range from 5.0% to 10.3% for all BPs and PWV measurements, and from 15.5% to 22.3% for AIx and AIx@75. RC expressed as percentages of maximal variation was <15% for the PWVs and ranged from 25.5% to 54.7% for BPs, AIx and AIx@75.Conclusions: The 24-h ambulatory brachial and central BPs and arterial measurements were reproducible within a short time period in Chinese, and could therefore be used in clinical practice and research settings.
引用
收藏
页码:250 / 257
页数:8
相关论文