Accuracy of pulse rate derived from 24-h ambulatory blood pressure monitoring compared with heart rate from 24-h Holter-ECG

被引:10
|
作者
Lauder, Lucas [1 ,2 ]
Scholz, Sean S. [1 ,2 ]
Ewen, Sebastian [1 ,2 ]
Lettner, Christine [1 ,2 ]
Ukena, Christian [1 ,2 ]
Bohm, Michael [1 ,2 ]
Mahfoud, Felix [1 ,2 ,3 ]
机构
[1] Univ Klinikum Saarlandes, Angiol & Internist Intens Med, Klin Innere Med 3, Homburg, Germany
[2] Saarland Univ, Saarbrucken, Germany
[3] MIT, Inst Med Engn & Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
ambulatory blood pressure monitoring; atrial fibrillation; blood pressure; heart rate; Holter-ECG; CARDIOVASCULAR-DISEASE; EUROPEAN-SOCIETY; RISK-FACTOR; HYPERTENSION; ASSOCIATION; MORTALITY; OUTCOMES; FAILURE; WOMEN; SHIFT;
D O I
10.1097/HJH.0000000000002566
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Resting heart rate (HR) associates with cardiovascular outcomes in the general population and in patients with hypertension and heart failure. The accuracy of pulse rate acquired by 24-h ambulatory blood pressure monitoring (ABPM-PR) in comparison with Holter-ECG HR (Holter-HR) is unknown. Objective: We aimed at investigating the accuracy of ABPM-PR when compared with Holter-HR. Methods and results: The current study included 1500 patients of a general cardiology outpatient unit undergoing simultaneous Holter and ABPM recordings. ABPM-PR differed marginally from Holter-HR by 0.55 bpm for 24-h average [95% confidence interval (CI): 0.37-0.73, P < 0.001], 1.27 bpm for daytime (95% CI: -0.98-1.56, P < 0.001) and 0.63 bpm for night-time (95% CI: 0.40-0.86 bpm; P < 0.001). The absolute delta between 24-h Holter-HR and ABPM-PR was less than 5 and less than 10 bpm in 1363 (91%) and 1458 (97%) patients, respectively. 24-h ABPM-PR more commonly underestimated than overestimated (7 versus 2%) 24-h Holter-HR by at least 5 bpm. The mean difference between Holter-HR and ABPM-PR was higher (+1.9 bpm; 95% CI: 0.9-3.0; P < 0.001) in patients with than without atrial fibrillation. There was no significant difference between Holter-HR and ABPM-PR in patients without supraventricular or ventricular extrasystoles (both P >= 0.750). Conclusion: ABPM-PR did not differ clinically meaningful from Holter-HR recordings in most patients and might be useful for risk prediction in hypertension.
引用
收藏
页码:2387 / 2392
页数:6
相关论文
共 50 条
  • [1] Does the mean 24-h pulse rate from ambulatory blood pressure monitoring reflect the mean 24-h ventricular rate from Holter electrocardiogram in atrial fibrillation patients?
    Tong, Hui-yu
    Yu, Jian-hua
    Hong, Kui
    Chen, Jing
    Liu, Hong-yu
    Su, Hai
    [J]. BLOOD PRESSURE MONITORING, 2020, 25 (06) : 332 - 337
  • [2] The effects of rofecoxib on 24-h ambulatory blood pressure and heart rate monitoring in patients with hypertension and osteoarthritis
    Derici, U
    Goker, B
    Ayerden-Ebinc, F
    Altok, RK
    Erten, Y
    Haznedaroglu, S
    Aydin, M
    Arinsoy, T
    Sindel, S
    [J]. INTERNATIONAL JOURNAL OF TISSUE REACTIONS-EXPERIMENTAL AND CLINICAL ASPECTS, 2005, 27 (02): : 69 - 73
  • [3] Limited reproducibility of 24-h ambulatory blood pressure monitoring
    Keren, Shay
    Leibowitz, Avshalom
    Grossman, Ehud
    Sharabi, Yehonatan
    [J]. CLINICAL AND EXPERIMENTAL HYPERTENSION, 2015, 37 (07) : 599 - 603
  • [4] Liraglutide increases 24-h heart rate by reducing the cardiac parasympathetic activity of patients with type 2 diabetes: power spectral analysis of heart rate variability on 24-h Holter ECG recordings
    Hara K.
    Aso Y.
    Komatsu T.
    Nakamachi T.
    Sakai Y.
    Takayanagi K.
    Kasai K.
    Inukai T.
    [J]. Diabetology International, 2015, 6 (1) : 26 - 32
  • [5] DISTRIBUTION OF 24-H AMBULATORY BLOOD PRESSURE IN CHILDREN
    Oh, Jun
    [J]. JOURNAL OF HYPERTENSION, 2016, 34 : E368 - E368
  • [6] Smoking related to 24-h ambulatory blood pressure and heart rate - A study in 352 normotensive Danish subjects
    Mikkelsen, KL
    Wiinberg, N
    Hoegholm, A
    Christensen, HR
    Bang, LE
    Nielsen, PE
    Svendsen, TL
    Kampmann, JP
    Madsen, NH
    Bentzon, MW
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1997, 10 (05) : 483 - 491
  • [7] Variation in heart rate range by 24-h Holter monitoring predicts heart failure in patients with atrial fibrillation
    Oikawa, Jun
    Fukaya, Hidehira
    Ishii, Shunsuke
    Nabeta, Takeru
    Nakamura, Hironori
    Ishizue, Naruya
    Kitasato, Lisa
    Kishihara, Jun
    Yamaoka-Tojo, Minako
    Niwano, Shinichi
    Ako, Junya
    [J]. ESC HEART FAILURE, 2022, 9 (05): : 3092 - 3100
  • [8] Modification of 24-h ambulatory blood pressure and heart rate during contraception with the vaginal ring: a prospective study
    Cagnacci, Angelo
    Zanin, Renata
    Napolitano, Antonella
    Arangino, Serenella
    Volpe, Annibale
    [J]. CONTRACEPTION, 2013, 88 (04) : 539 - 543
  • [9] Dynamics of the states of heart rate regulation during 24-h monitoring
    Dzizinskii A.A.
    Kuklin S.G.
    Mikhalevich I.M.
    Rozhkova N.Yu.
    [J]. Human Physiology, 2005, 31 (2) : 195 - 198
  • [10] 24-h systolic blood pressure and heart rate recordings in lean and obese adolescents
    Framme, Jenny
    Dangardt, Frida
    Marild, Staffan
    Osika, Walter
    Wahrborg, Peter
    Friberg, Peter
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (04) : 235 - 239