Variation in heart rate range by 24-h Holter monitoring predicts heart failure in patients with atrial fibrillation

被引:1
|
作者
Oikawa, Jun [1 ]
Fukaya, Hidehira [1 ]
Ishii, Shunsuke [1 ]
Nabeta, Takeru [1 ]
Nakamura, Hironori [1 ]
Ishizue, Naruya [1 ]
Kitasato, Lisa [1 ]
Kishihara, Jun [1 ]
Yamaoka-Tojo, Minako [2 ]
Niwano, Shinichi [1 ]
Ako, Junya [1 ]
机构
[1] Kitasato Univ, Dept Cardiovasc Med, Sch Med, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ, Dept Rehabil, Sch Allied Hlth Sci, Sagamihara, Kanagawa, Japan
来源
ESC HEART FAILURE | 2022年 / 9卷 / 05期
关键词
Heart failure; Atrial fibrillation; Heart rate range; 24-h Holter electrocardiogram; BETA-BLOCKERS; RHYTHM; PREVALENCE; MORTALITY; STROKE; DEATH;
D O I
10.1002/ehf2.14035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The analysis of heart rate (HR) changes, such as the HR variability or HR turbulence, has been reported as a marker of cardiovascular events during sinus rhythm; however, those relationships during atrial fibrillation (AF) remain controversial, and those parameters are not commonly used in AF patients. We sought to investigate the relationship between a simple index focused on the HR and heart failure (HF) events in patients with permanent AF. Methods and results We enrolled 198 patients with permanent AF and evaluated the HR range, defined as the maximum HR minus the minimum HR on 24-h Holter electrocardiogram recordings. The patients were divided into two groups, i.e., the larger (n = 101) and smaller (n = 97) HR range (HRR) groups, determined by the median value. The HF events were defined as hospitalizations for HF or urgent hospital visits due to exacerbations of one's HF status. The observation period of this study was set at 5 years from registration. The median age was 73 (68-77) years, and 29% were female. The median HRR was 84 (63-118) beats per minutes (bpm). During the observational period of 1825 days (median), HF events occurred in 37 (0.047 per patient-year) patients. In a log-rank test, the larger HRR group had more frequent HF events than the smaller HRR group (P = 0.0078). In the adjusted Cox proportional hazards model using the significantly different factors from the univariate analysis (Model 1) and factors and medications associated with HF (Model 2), the larger HRR group had a higher prevalence of HF events than the smaller HRR group for both models [Model 1, adjusted hazard ratio = 3.21, 95% confidence interval (CI) 1.593-6.708, P = 0.0009; Model 2, adjusted hazard ratio = 3.12, 95% CI 1.522-6.685, P = 0.002]. When analysed using the time-dependent Cox proportional hazards model, the HRR was associated with HF with a statistically significant difference in both the univariate and multivariate analyses [hazard ratio = 1.01, 95% CI 1.006-1.020, P = 0.0002; Model 1, adjusted hazard ratio = 1.02, 95% CI 1.011-1.027, P < 0.0001; Model 2, adjusted hazard ratio = 1.01, 95% CI 1.008-1.021, P = 0.0003). There was no significant difference in the chronotropic medications between the two groups. Conclusions In patients with permanent AF, a larger HRR was associated with HF events.
引用
收藏
页码:3092 / 3100
页数:9
相关论文
共 50 条
  • [1] Does the mean 24-h pulse rate from ambulatory blood pressure monitoring reflect the mean 24-h ventricular rate from Holter electrocardiogram in atrial fibrillation patients?
    Tong, Hui-yu
    Yu, Jian-hua
    Hong, Kui
    Chen, Jing
    Liu, Hong-yu
    Su, Hai
    [J]. BLOOD PRESSURE MONITORING, 2020, 25 (06) : 332 - 337
  • [2] Daily heart rate variability predicts heart failure events in patients with permanent atrial fibrillation
    Oikawa, J.
    Fukaya, H.
    Nabeta, T.
    Arakawa, Y.
    Horiguchi, A.
    Nishinarita, R.
    Nakamura, H.
    Satoh, A.
    Kishihara, J.
    Ishii, S.
    Noda, C.
    Yamaoka-Tojo, M.
    Niwano, S.
    Ako, J.
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 : 192 - 192
  • [3] Is Heart Rate Important for Patients With Heart Failure in Atrial Fibrillation?
    Cullington, Damien
    Goode, Kevin M.
    Zhang, Jufen
    Cleland, John G. F.
    Clark, Andrew L.
    [J]. JACC-HEART FAILURE, 2014, 2 (03) : 213 - 220
  • [4] Accuracy of pulse rate derived from 24-h ambulatory blood pressure monitoring compared with heart rate from 24-h Holter-ECG
    Lauder, Lucas
    Scholz, Sean S.
    Ewen, Sebastian
    Lettner, Christine
    Ukena, Christian
    Bohm, Michael
    Mahfoud, Felix
    [J]. JOURNAL OF HYPERTENSION, 2020, 38 (12) : 2387 - 2392
  • [5] What is the appropriate heart rate control of atrial fibrillation for prevention of heart failure? Relation between 24-hour Holter recordings and subsequent heart failure
    Hirano, K.
    Yamashita, T.
    Suzuki, S.
    Otsuka, T.
    Sugiyama, H.
    Sagara, K.
    Sawada, H.
    Aizawa, T.
    Fu, L. T.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 410 - 410
  • [6] Influence of heart rate on prognosis of patients with heart failure and atrial fibrillation
    Mareev, Y.
    Petruchina, A.
    Goryunova, T.
    Sokolov, S.
    Mareev, V.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 29 - 30
  • [7] HEART RATE IS NOT RELATED TO SURVIVAL IN PATIENTS WITH HEART FAILURE AND ATRIAL FIBRILLATION
    Hawkey, Sean
    Levin, Daniel
    Mohan, Mohapradeep
    Baig, Fatima
    Iskandar, Muhammad
    Rutherford, Lynn
    Lang, Chim
    Choy, Anna
    [J]. HEART, 2015, 101 : A15 - A16
  • [8] Heart rate is not related to survival in patients with heart failure and atrial fibrillation
    Hawkey, S.
    Levin, D.
    Mohan, M.
    Baig, F.
    Rutherford, L.
    Iskandar, M.
    Lang, C. H. I. M.
    Choy, A.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 177 - 177
  • [9] Relationship between 24-h Holter recordings and clinical outcomes in patients with permanent atrial fibrillation
    Hirano, Keiko
    Yamashita, Takeshi
    Suzuki, Shinya
    Hayama, Etsuko
    Matsuoka, Joe
    Otsuka, Takayuki
    Sagara, Koichi
    Fu, Long-tai
    Sawada, Hitoshi
    Aizawa, Tadanori
    Nakazato, Yuji
    Daida, Hiroyuki
    [J]. JOURNAL OF CARDIOLOGY, 2012, 60 (1-2) : 42 - 46
  • [10] Liraglutide increases 24-h heart rate by reducing the cardiac parasympathetic activity of patients with type 2 diabetes: power spectral analysis of heart rate variability on 24-h Holter ECG recordings
    Hara K.
    Aso Y.
    Komatsu T.
    Nakamachi T.
    Sakai Y.
    Takayanagi K.
    Kasai K.
    Inukai T.
    [J]. Diabetology International, 2015, 6 (1) : 26 - 32