The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties

被引:138
|
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Dept Orthopaed Surg, B-2100 Deurne, Belgium
[3] Medivision, CH-4436 Oberdorf, Switzerland
[4] Univ Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[5] Ruhr Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
[6] Alfried Krupp Krankenhaus Essen, Dept Orthopaed Surg, D-45117 Essen, Germany
[7] Dept Surg, D-42109 Wuppertal, Germany
[8] Heidelberg Univ, BG Unfallklin Ludwigshafen, Dept Traumatol, D-67071 Ludwigshafen, Germany
[9] Marienkrankenhaus Kaiserswerth, Dept Orthopaed Surg, D-40348 Dusseldorf, Germany
[10] Ruhr Univ Bochum, Dept Med Informat Biometr & Epidemiol, D-44801 Bochum, Germany
[11] Girardet Klin Essen, Dept Orthopaed Surg, D-45131 Essen, Germany
关键词
D O I
10.1007/s00264-004-0542-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8degrees+/-10.1degrees (range: 23.0-71.5degrees) and mean anteversion angle was 27.3degrees+/-15.0degrees (range: -23.5degrees to 59.0degrees). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [21] A Prospective, Randomized Study of Surgical Positioning Software Shows Improved Cup Placement in Total Hip Arthroplasty
    Hamilton, William G.
    Parks, Nancy L.
    McDonald, James F., III
    Pfefferle, Kiel J.
    ORTHOPEDICS, 2019, 42 (01) : 42 - 47
  • [22] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [23] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Fujita, Masahiro
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Maeda, Toshihisa
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7229 - 7235
  • [24] Comparison of the accuracy of CT- and accelerometer-based navigation systems for cup orientation in total hip arthroplasty
    Tetsunaga, Tomonori
    Yamada, Kazuki
    Tetsunaga, Tomoko
    Furumatsu, Takayuki
    Sanki, Tomoaki
    Kawamura, Yoshi
    Ozaki, Toshifumi
    HIP INTERNATIONAL, 2021, 31 (05) : 603 - 608
  • [25] Accuracy of acetabular cup placement using CT-based navigation in total hip arthroplasty: Comparison between obese and non-obese patients
    Imai, Norio
    Takubo, Ryota
    Suuzki, Hayato
    Shimada, Hayato
    Miyasaka, Dai
    Tsuchiya, Kazuki
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (03) : 482 - 487
  • [26] Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens
    Kievit, Arthur J.
    Dobbe, Johannes G. G.
    Mallee, Wouter H.
    Blankevoort, Leendert
    Streekstra, Geert J.
    Schafroth, Matthias U.
    HIP INTERNATIONAL, 2021, 31 (01) : 58 - 65
  • [27] Rigid fixation of pelvic tracker essential for accurate cup placement in CT-based navigation total hip arthroplasty
    Hamawaki, Makoto
    Hamada, Hidetoshi
    Uemura, Keisuke
    Takashima, Kazuma
    Mae, Hirokazu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (04) : 403 - 409
  • [28] Relationship between the Accuracy of the Acetabular Cup Angle and BMI in Posterolateral Total Hip Arthroplasty with CT-Based Navigation
    Ishikura, Hisatoshi
    Nakamura, Masaki
    Nakamura, Shigeru
    Tanaka, Takeyuki
    Kawano, Hirotaka
    Tanaka, Sakae
    MEDICINA-LITHUANIA, 2022, 58 (07):
  • [29] Accuracy and reproducibility of visual estimation of the acetabular cup positioning in total hip arthroplasty on plain radiographs by orthopaedic surgeons
    Somerville, Charlotte M. B.
    Geddes, James Arthur
    Tofighi, Mehdi
    Boddu, Krishna
    JOURNAL OF PERIOPERATIVE PRACTICE, 2022, 32 (10) : 265 - 269
  • [30] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    SCIENTIFIC REPORTS, 2023, 13 (01)