The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties

被引:138
|
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Dept Orthopaed Surg, B-2100 Deurne, Belgium
[3] Medivision, CH-4436 Oberdorf, Switzerland
[4] Univ Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[5] Ruhr Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
[6] Alfried Krupp Krankenhaus Essen, Dept Orthopaed Surg, D-45117 Essen, Germany
[7] Dept Surg, D-42109 Wuppertal, Germany
[8] Heidelberg Univ, BG Unfallklin Ludwigshafen, Dept Traumatol, D-67071 Ludwigshafen, Germany
[9] Marienkrankenhaus Kaiserswerth, Dept Orthopaed Surg, D-40348 Dusseldorf, Germany
[10] Ruhr Univ Bochum, Dept Med Informat Biometr & Epidemiol, D-44801 Bochum, Germany
[11] Girardet Klin Essen, Dept Orthopaed Surg, D-45131 Essen, Germany
关键词
D O I
10.1007/s00264-004-0542-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8degrees+/-10.1degrees (range: 23.0-71.5degrees) and mean anteversion angle was 27.3degrees+/-15.0degrees (range: -23.5degrees to 59.0degrees). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [31] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    Scientific Reports, 13
  • [32] Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Mitsutake, Ryo
    Ito, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [33] Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study
    Hiromasa Tanino
    Yasuhiro Nishida
    Ryo Mitsutake
    Hiroshi Ito
    BMC Musculoskeletal Disorders, 22
  • [34] Efficacy of Computed Tomography-Based Navigation for Cup Placement in Revision Total Hip Arthroplasty
    Kubota, Yuta
    Kaku, Nobuhiro
    Tabata, Tomonori
    Tagomori, Hiroaki
    Tsumura, Hiroshi
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (01) : 43 - 51
  • [35] Accuracy of cup placement using computed tomography-based navigation system in total hip arthroplasty through the direct anterior approach
    Matsuki, Yuta
    Imagama, Takashi
    Tokushige, Atsunori
    Yamazaki, Kazuhiro
    Sakai, Takashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (02) : 370 - 375
  • [36] Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement
    Kalteis, T
    Handel, M
    Herold, T
    Perlick, L
    Paetzel, C
    Grifka, J
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) : 294 - 300
  • [37] Accuracy of imageless navigation for functional cup positioning and restoration of leg length in total hip arthroplasty: a matched comparative analysis
    Meftah, Morteza
    Siddappa, Vinay Hosuru
    Muir, Jeffrey M.
    CURRENT ORTHOPAEDIC PRACTICE, 2021, 32 (01): : 48 - 52
  • [38] Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty
    Nemati, Hassan M.
    Christensson, Albin
    Pettersson, Andreas
    Nemeth, Gunnar
    Flivik, Gunnar
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [39] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [40] Accuracy of acetabular cup placement using an angle-adjusting alignment guide with laser pointer in total hip arthroplasty
    Okanoue, Yusuke
    Aso, Koji
    Dan, Junpei
    Takaya, Shogo
    Izumi, Masashi
    Kawakami, Teruhiko
    Ikeuchi, Masahiko
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)