The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties

被引:138
|
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Dept Orthopaed Surg, B-2100 Deurne, Belgium
[3] Medivision, CH-4436 Oberdorf, Switzerland
[4] Univ Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[5] Ruhr Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
[6] Alfried Krupp Krankenhaus Essen, Dept Orthopaed Surg, D-45117 Essen, Germany
[7] Dept Surg, D-42109 Wuppertal, Germany
[8] Heidelberg Univ, BG Unfallklin Ludwigshafen, Dept Traumatol, D-67071 Ludwigshafen, Germany
[9] Marienkrankenhaus Kaiserswerth, Dept Orthopaed Surg, D-40348 Dusseldorf, Germany
[10] Ruhr Univ Bochum, Dept Med Informat Biometr & Epidemiol, D-44801 Bochum, Germany
[11] Girardet Klin Essen, Dept Orthopaed Surg, D-45131 Essen, Germany
关键词
D O I
10.1007/s00264-004-0542-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8degrees+/-10.1degrees (range: 23.0-71.5degrees) and mean anteversion angle was 27.3degrees+/-15.0degrees (range: -23.5degrees to 59.0degrees). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [41] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Cho, Eiji
    Hisatome, Takashi
    Oda, Shuhei
    Fujimaki, Hirohisa
    Nakanishi, Kazuyoshi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [42] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Eiji Cho
    Takashi Hisatome
    Shuhei Oda
    Hirohisa Fujimaki
    Kazuyoshi Nakanishi
    Journal of Orthopaedic Surgery and Research, 17
  • [43] Accuracy and precision of the measurement of liner orientation of dual mobility cup total hip arthroplasty using ultrasound imaging
    Riglet, Louis
    Viste, Anthony
    De Leissegues, Tristan
    Naaim, Alexandre
    Liebgott, Herve
    Dumas, Raphael
    Fessy, Michel Henri
    Gras, Laure-Lise
    MEDICAL ENGINEERING & PHYSICS, 2022, 108
  • [44] The Accuracy of Acetabular Cup Positioning Using Patient-Specific 3D Orientation Guidance in Total Hip Arthroplasty
    McMahon, Stephen J.
    Christmas, Maxim U. S., I
    McMahon, Jack
    Pierrepont, Jim
    McMahon, Ryan
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [45] Free-hand CT-based electromagnetically guided interventions: Accuracy, efficiency and dose usage
    Penzkofer, Tobias
    Bruners, Philipp
    Isfort, Peter
    Schoth, Felix
    Guenther, Rolf W.
    Schmitz-Rode, Thomas
    Mahnken, Andreas H.
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2011, 20 (04) : 226 - 233
  • [46] A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position
    Ohyama, Yohei
    Minoda, Yukihide
    Sugama, Ryo
    Masuda, Sho
    Ohta, Yoichi
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2865 - 2872
  • [47] Accuracy of Cup Placement Angle, Leg Lengthening, and Offset Measurement Using an AR-Based Portable Navigation System: Validation in Supine and Lateral Decubitus Positions for Total Hip Arthroplasty
    Ozaki, Yusuke
    Yamamoto, Takeaki
    Kimura, Satomi
    Kasai, Toru
    Niki, Rintaro
    Niki, Hisateru
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [48] Accuracy of angle and position of the cup using computed tomography-based navigation systems in total hip arthroplasty
    Iwana, Daiki
    Nakamura, Nobuo
    Miki, Hidenobu
    Kitada, Makoto
    Hananouchi, Takehito
    Sugano, Nobuhiko
    COMPUTER AIDED SURGERY, 2013, 18 (5-6) : 187 - 194
  • [49] Smartphone Application Helps Improve the Accuracy of Cup Placement by Young, Less-Experienced Surgeons during Primary Total Hip Arthroplasty
    Khalifa, Ahmed A.
    Abdelnasser, Mohammad K.
    Ahmed, Ahmed M.
    Shetty, Gautam M.
    Abdelaal, Ahmed M.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (03): : 278 - 285
  • [50] Proposal of accurate cup placement procedure during total hip arthroplasty based on pelvic tilt discrepancies in the lateral position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Sakai, Akinori
    SCIENTIFIC REPORTS, 2021, 11 (01)