Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position

被引:2
|
作者
Fujita, Masahiro [1 ]
Hayashi, Shinya [1 ]
Kuroda, Yuichi [1 ]
Nakano, Naoki [1 ]
Maeda, Toshihisa [1 ]
Matsushita, Takehiko [1 ]
Matsumoto, Tomoyuki [1 ]
Kuroda, Ryosuke [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Orthoped Surg, 7-5-1 Kusunoki Cho, Chuo Ku, Kobe, Hyogo 6500017, Japan
关键词
Total hip arthroplasty; Cup positioning; Portable navigation system; Accelerometer-based navigation; Augmented reality-based navigation; ACETABULAR COMPONENT; SPINAL DEFORMITY; ANTEVERSION; NAVIGATION; FRACTURES; PATIENT;
D O I
10.1007/s00402-023-04975-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study is to compare the accuracy of acetabular cup positioning between the accelerometer-based navigation system and the augmented reality-based navigation system during THA in the supine position.Materials and methodsThis retrospective study included 66 patients (70 hips) who underwent THA using two types of portable navigation system, Hip Align or AR-Hip, in the spine position. The absolute difference between the intraoperative navigation record and postoperative measurement using computed tomography data was evaluated. Preoperative clinical factors that decreased the accuracy of cup positioning by & GE; 3 & DEG; were analyzed via multiple logistic regression analyses.ResultsThe average absolute error of inclination was 2.8 & PLUSMN; 2.6 & DEG; in Hip Align and 2.7 & PLUSMN; 1.8 & DEG; in AR-Hip, and absolute anteversion error was 2.5 & PLUSMN; 2.0 & DEG; in Hip Align and 2.6 & PLUSMN; 2.2 & DEG; in AR-Hip, and there was no significantly different between the two navigation systems. There was a significant association between the absolute measurement error (& GE; 3 & DEG;) of cup inclination and patients' BMI in the Hip Align group [odds ratio (OR) 1.350; 95% confidence interval (CI) 1.035-1.760; p = 0.027], but not in the AR-Hip group.ConclusionsThe accuracy of the acetabular cup positioning between the Hip Align and AR-Hip showed no difference during THA in the spine position. The high BMI could have negative influence on the accuracy of cup positioning in THA using Hip Align, thus AR-Hip could be designable for obesity patients.
引用
收藏
页码:7229 / 7235
页数:7
相关论文
共 50 条
  • [1] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [2] Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position
    Okamoto, Masanori
    Kawasaki, Masashi
    Okura, Toshiaki
    Ochiai, Satoshi
    Yokoi, Hiroyuki
    [J]. HIP INTERNATIONAL, 2021, 31 (04) : 492 - 499
  • [3] Poor accuracy of freehand cup positioning during total hip arthroplasty
    B. H. Bosker
    C. C. P. M. Verheyen
    W. G. Horstmann
    N. J. A. Tulp
    [J]. Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 375 - 379
  • [4] Poor accuracy of freehand cup positioning during total hip arthroplasty
    Bosker, B. H.
    Verheyen, C. C. P. M.
    Horstmann, W. G.
    Tulp, N. J. A.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) : 375 - 379
  • [5] Cup positioning in total hip arthroplasty
    Scheerlinck, Thierry
    [J]. ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 336 - 347
  • [6] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    [J]. ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [7] A Fluoroscopic Grid in Supine Total Hip Arthroplasty Improving Cup Position, Limb Length, and Hip Offset
    Gililland, Jeremy M.
    Anderson, Lucas A.
    Boffeli, Shannon L.
    Pelt, Christopher E.
    Peters, Christopher L.
    Kubiak, Erik N.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 111 - 116
  • [8] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    [J]. Scientific Reports, 13
  • [10] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Cho, Eiji
    Hisatome, Takashi
    Oda, Shuhei
    Fujimaki, Hirohisa
    Nakanishi, Kazuyoshi
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)