Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position

被引:25
|
作者
Okamoto, Masanori [1 ]
Kawasaki, Masashi [1 ]
Okura, Toshiaki [1 ]
Ochiai, Satoshi [2 ]
Yokoi, Hiroyuki [1 ]
机构
[1] Aichi Koseiren Konan Kosei Hosp, Dept Orthopaed Surg, 137 Omatsubara,Takaya Cho, Konan, Aichi 4838704, Japan
[2] Nagoya Univ, Dept Orthopaed Surg, Grad Sch Med, Nagoya, Aichi, Japan
关键词
Accelerometer; acetabular alignment guide; cup placement; HipAlign; navigation; total hip arthroplasty; ACETABULAR COMPONENT; SAFE ZONE; WEAR; DISLOCATION; IMPROVEMENT; PLACEMENT; ANGLE; RISK;
D O I
10.1177/1120700020908788
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accelerometer-based portable navigation systems in supine total hip arthroplasty (THA) have been developed, but there are no reports on the accuracy of cup placement. We aimed to investigate and compare the accuracy of the accelerometer-based portable navigation system versus the acetabular alignment guide placed on the pelvis in THA using the direct anterior approach (DAA). Both devices tracked changes in the pelvic position. Methods: In this single-centre, retrospective study, we reviewed 115 hips in 113 patients who underwent primary THA via the DAA using an accelerometer-based portable navigation system in the supine position (portable navigation group) and 106 hips in 101 patients who underwent THA using an acetabular alignment guide (alignment guide group) as controls. Hips were evaluated postoperatively using computed tomography to measure cup orientation. The accuracy of cup orientation was compared between the 2 groups. Results: Absolute values of inclination error were 3.1 degrees +/- 2.2 degrees and 2.9 degrees +/- 2.3 degrees (p = 0.708) in the portable navigation and alignment guide groups and those of anteversion error were 2.8 degrees +/- 2.3 degrees and 3.7 degrees +/- 2.7 degrees, respectively (p = 0.005). The number of cups placed within 10 degrees of error was 98.3% and 96.2% in the portable navigation and alignment guide groups, respectively (p = 0.304). The portable navigation group had significantly more hips (72.2%) placed within a 5 degrees margin of error than did the alignment guide group (56.6%) (p = 0.016). Conclusion: High accuracy in cup placement was achieved using accelerometer-based portable navigation in supine THA. Using a navigation system may contribute to improved long-term outcomes.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [1] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    [J]. Scientific Reports, 13
  • [2] Registration in the supine position improve the accuracy of cup placement in total hip arthroplasty using a portable navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [3] Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position
    Kamenaga, Tomoyuki
    Hayashi, Shinya
    Hashimoto, Shingo
    Matsumoto, Tomoyuki
    Takayama, Koji
    Fujishiro, Takaaki
    Hiranaka, Takafumi
    Niikura, Takahiro
    Kuroda, Ryosuke
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [4] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [5] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Fujita, Masahiro
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Maeda, Toshihisa
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7229 - 7235
  • [6] Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position
    Okamoto, Masanori
    Takegami, Yasuhiko
    Osawa, Yusuke
    Tanaka, Shinya
    Nobori, Tatsuya
    Imagama, Shiro
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024,
  • [7] Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Akihiro Sudo
    [J]. BMC Musculoskeletal Disorders, 23
  • [8] Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [9] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    [J]. ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [10] Accuracy of angle and position of the cup using computed tomography-based navigation systems in total hip arthroplasty
    Iwana, Daiki
    Nakamura, Nobuo
    Miki, Hidenobu
    Kitada, Makoto
    Hananouchi, Takehito
    Sugano, Nobuhiko
    [J]. COMPUTER AIDED SURGERY, 2013, 18 (5-6) : 187 - 194