Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac

被引:0
|
作者
Han, Eun Young [1 ]
Aima, Manik [1 ]
Hughes, Neil [2 ]
Briere, Tina M. [1 ]
Yeboa, Debra N. [2 ]
Castillo, Pam [2 ]
Wang, Jihong [1 ]
Yang, Jinzhong [1 ]
Vedam, Sastry [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94,1515 Holcomb Blvd, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2020年 / 7卷 / 02期
关键词
Spine SBRT; Unity MR-Linac; TrueBeam; MAGNETIC-FIELD; MONTE-CARLO; REFERENCE DOSIMETRY; ACCELERATOR; OPTIMIZATION; METASTASES; SCANNER; IMPACT;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The Elekta Unity MR-Linac (MRL) is expected to benefit spine stereotactic body radiotherapy (SBRT) due to the improved soft tissue contrast available with onboard MR imaging. However, the irradiation geometry and beam configuration of the MRL deviates from the conventional linear accelerator (Linac). The purpose of the study was to investigate the feasibility of spine SBRT on the MRL. Treatment plans were generated for lumbar and thoracic spines. Target and spinal cord doses were measured with two cylindrical ion chambers inserted into an anthropomorphic spine phantom. Our study indicated that the Monaco treatment planning system (TPS) could generate clinical treatment plans for the MRL that were of comparable quality to the RayStation TPS with a conventional Linac. For both Linacs the planned dose within the gross tumor volume agreed with measurements within +/- 3%. For the spinal cord, while the measured doses from the TrueBeam were 1.8% higher for the lumbar spine plan and 6.9% higher for thoracic spine plan, the measured doses from MRL were 0.6% lower for the lumbar spine plan and 3.9% higher for the thoracic spine plan. In conclusion, the feasibility of spine SBRT in Elekta Unity MRL has been demonstrated, however, more effort is needed for such as optimizing the online plan adaptation method.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 50 条
  • [21] Linac commissioning methodology for the Elekta Unity MR Linac
    Hanson, I.
    Nill, S.
    Chick, J.
    Oelfke, U.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S575 - S575
  • [22] Out-Of-Field Radiation Dose Considerations in Partial Breast Irradiation with Elekta Unity MR-Linac - a Feasibility Study
    Muruganandham, M.
    Lee, B.
    Vedam, S.
    Wang, J.
    Yang, J.
    Salehpour, M.
    Shaitelman, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E645 - E645
  • [23] Variation in isocentre location of an Elekta Unity MR-linac through full gantry rotation
    Hunt, James R.
    Ebert, Martin A.
    Rowshanfarzad, Pejman
    Riis, Hans L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (01):
  • [24] Dose Accumulation of Daily Adaptive Plans Using MiM and RayStation for Elekta Unity MR-Linac
    Lee, D.
    Oh, S.
    Pavord, D.
    Colonias, A.
    Fuhrer, R.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Monte Carlo study of small-field dosimetry for an ELEKTA Unity MR-Linac system
    Yano, Masayuki
    Araki, Fujio
    Ohno, Takeshi
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 194
  • [26] Assessing Artefacts of Cardiac Pacemakers and Leads at a 1.5T Elekta Unity MR-Linac
    Lee, D.
    Trombetta, M.
    Shaw, G.
    Oh, S.
    Hwang, M.
    Pavord, D.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E183 - E183
  • [27] Feasibility Study of Esophagus Adaptive Planning Using Elekta MR-Linac Beam Model
    Wen, Z.
    Pollard, J.
    Ibbott, G.
    Lin, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [28] Experimental Verification of the Electron Return Effect in Lung Heterogeneity Measurements On Elekta Unity MR-Linac
    Tyagi, N.
    Liang, J.
    Scripes, P.
    Subashi, E.
    Moran, J.
    Chan, M.
    Lim, S.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E769 - E769
  • [29] Beam and Cryostat Scatter Characteristics of the Elekta MR-Linac
    Duglio, M.
    Towe, S.
    Roberts, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3442 - 3442
  • [30] MRI B0 homogeneity and geometric distortion with continuous linac gantry rotation on an Elekta Unity MR-linac
    Jackson, Steven
    Glitzner, Markus
    Tijssen, Rob H. N.
    Raaymakers, Bas W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):