Out-Of-Field Radiation Dose Considerations in Partial Breast Irradiation with Elekta Unity MR-Linac - a Feasibility Study

被引:0
|
作者
Muruganandham, M. [1 ]
Lee, B. [2 ]
Vedam, S. [3 ]
Wang, J. [4 ]
Yang, J. [4 ]
Salehpour, M. [4 ]
Shaitelman, S. [4 ]
机构
[1] MD Anderson Canc Ctr, Sugar Land, TX USA
[2] UT MD Anderson, Houston, UT USA
[3] UT MD Anderson Canc Ctr, Houston, TX USA
[4] MD Anderson Canc Ctr, Houston, TX USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GeP-M-3
引用
收藏
页码:E645 / E645
页数:1
相关论文
共 50 条
  • [1] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    John Baines
    Marcus Powers
    Glen Newman
    [J]. Physical and Engineering Sciences in Medicine, 2021, 44 : 1049 - 1059
  • [2] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    Baines, John
    Powers, Marcus
    Newman, Glen
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (04) : 1049 - 1059
  • [3] Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac
    Han, Eun Young
    Aima, Manik
    Hughes, Neil
    Briere, Tina M.
    Yeboa, Debra N.
    Castillo, Pam
    Wang, Jihong
    Yang, Jinzhong
    Vedam, Sastry
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 127 - 134
  • [4] Out-of-field dose and its constituent components for a 1.5 T MR-Linac
    Yang, Bin
    Tang, Ka Keung
    Huang, Chen-Yu
    Geng, Hui
    Lam, Wai Wang
    Wong, Yeung Sum
    Tse, Mei Yan
    Lau, Ka Ki
    Cheung, Kin Yin
    Yu, Siu Ki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22):
  • [5] An Independent Dose Calculation Method for MR-Guided Radiotherapy with Elekta Unity MR-Linac
    Chen, X.
    Hwang, M.
    Oh, S.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E208 - E208
  • [6] Monte Carlo study of small-field dosimetry for an ELEKTA Unity MR-Linac system
    Yano, Masayuki
    Araki, Fujio
    Ohno, Takeshi
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 194
  • [7] Out-of-field dose assessment for a 1.5 T MR-Linac with optically stimulated luminescence dosimeters
    Zhang, Yan
    Yan, Shaojie
    Cui, Zhen
    Wang, Yungang
    Li, Zhenjiang
    Yin, Yong
    Li, Baosheng
    Quan, Hong
    Zhu, Jian
    [J]. MEDICAL PHYSICS, 2021, 48 (07) : 4027 - 4037
  • [8] Dose Accumulation of Daily Adaptive Plans Using MiM and RayStation for Elekta Unity MR-Linac
    Lee, D.
    Oh, S.
    Pavord, D.
    Colonias, A.
    Fuhrer, R.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Feasibility Study of Esophagus Adaptive Planning Using Elekta MR-Linac Beam Model
    Wen, Z.
    Pollard, J.
    Ibbott, G.
    Lin, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [10] Evaluation of patient positioning for accelerated partial breast irradiation on an MR-Linac
    Davies, L.
    McDaid, L.
    Anandadas, C.
    Whiteside, L.
    Clough, A.
    Benson, R.
    Amaro, P. Fendall
    Parker, J.
    Drury-Smith, H.
    Eccles, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S401 - S402