Fluence to local skin absorbed dose and dose equivalent conversion coefficients for monoenergetic positrons using Monte-Carlo code MCNP6

被引:4
|
作者
Bourgois, L. [1 ]
Antoni, R. [2 ]
机构
[1] CEA, DAM, DIF, F-91297 Bruyeres Le Chatel, Arpajon, France
[2] CEA, DEN, CAD, F-13108 St Paul Les Durance, France
关键词
Skin dose; MCNP6; Local-Skin equivalent Dose; Positrons; INCIDENT;
D O I
10.1016/j.apradiso.2015.11.029
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Conversion coefficients fluence to local skin equivalent dose, as introduced in ICRP Publication 116, 2010, are calculated for positrons of energies ranging from 10 keV to 10 MeV using the code MCNP6. Fluence to dose equivalent conversion coefficients H'(0.07,0 degrees)/Phi are calculated for positrons of energy ranging between 20 keV and 10 MeV. A comparison between operational dose quantity H'(0.07,0 degrees) and the Local-Skin equivalent Dose shows an overall good agreement between these two quantities, except between 60 keV and 100 key. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:372 / 376
页数:5
相关论文
共 50 条
  • [21] ESTIMATION OF SHALLOW DOSE EQUIVALENT FOR BETA-RAYS USING A MONTE-CARLO CALCULATION
    SUGAI, K
    KAI, M
    KUSAMA, T
    YOSHIZAWA, Y
    HEALTH PHYSICS, 1985, 49 (02): : 376 - 376
  • [22] WALL-CORRECTION AND ABSORBED-DOSE CONVERSION FACTORS FOR FRICKE DOSIMETRY - MONTE-CARLO CALCULATIONS AND MEASUREMENTS
    MA, CM
    ROGERS, DWO
    SHORTT, KR
    ROSS, CK
    NAHUM, AE
    BIELAJEW, AF
    MEDICAL PHYSICS, 1993, 20 (02) : 283 - 292
  • [23] MONTE-CARLO CALCULATIONS OF MONOENERGETIC ELECTRON DEPTH-DOSE DISTRIBUTIONS IN LIF CHIPS - SKIN DOSE CORRECTION FACTORS FOR BETA-RAYS
    HOROWITZ, YS
    HIRNING, CR
    YUEN, P
    WONG, P
    HEALTH PHYSICS, 1994, 67 (04): : 330 - 337
  • [24] Dose-Area Product to Effective Dose Conversion Coefficients for Pelvic Radiography Using a Monte Carlo Program
    Chen, David S.
    Escobedo, Eva M.
    Eastman, Jonathan G.
    Bloomstein, Joshua D.
    Taylor, Sandra L.
    Seibert, J. Anthony
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (03) : 679 - 684
  • [25] GENERATION OF PHOTON DOSE SPREAD ARRAYS USING THE EGS4 MONTE-CARLO CODE
    MACKIE, TR
    BLAIR, A
    BIELAJEW, AF
    ROGERS, DWO
    BATTISTA, JJ
    MEDICAL PHYSICS, 1985, 12 (04) : 515 - 515
  • [26] Benchmarking of stray neutron fields produced by synchrocyclotrons and synchrotrons in compact protontherapy centers (CPTC) using MCNP6 Monte Carlo code
    Garcia-Fernandez, Gonzalo F.
    Gallego, Eduardo
    Gomez-Ros, Jose M.
    Vega-Carrilloc, Hector R.
    Guzman-Garcia, Karen A.
    Cevallos-Robalino, Lenin E.
    Garcia-Baonza, Roberto
    Hernandez, Eduardo Fuentes
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [27] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [28] Using the Monte Carlo technique to calculate dose conversion coefficients for medical professionals in interventional radiology
    Santos, W. S.
    Carvalho, A. B., Jr.
    Hunt, J. G.
    Maia, A. F.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 177 - 180
  • [29] Fluence-to-dose conversion coefficients based on the VIP-MAN anatomical model and mcnpx code for monoenergetic neutrons above 20 MeV
    Bozkurt, A
    Chao, TC
    Xu, XG
    HEALTH PHYSICS, 2001, 81 (02): : 184 - 202
  • [30] The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code
    Zhang, Bintuan
    Dang, Bingrong
    Wang, Zhuanzi
    Wei, Wei
    Li, Wenjian
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 514 - 517