Fluence to local skin absorbed dose and dose equivalent conversion coefficients for monoenergetic positrons using Monte-Carlo code MCNP6

被引:4
|
作者
Bourgois, L. [1 ]
Antoni, R. [2 ]
机构
[1] CEA, DAM, DIF, F-91297 Bruyeres Le Chatel, Arpajon, France
[2] CEA, DEN, CAD, F-13108 St Paul Les Durance, France
关键词
Skin dose; MCNP6; Local-Skin equivalent Dose; Positrons; INCIDENT;
D O I
10.1016/j.apradiso.2015.11.029
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Conversion coefficients fluence to local skin equivalent dose, as introduced in ICRP Publication 116, 2010, are calculated for positrons of energies ranging from 10 keV to 10 MeV using the code MCNP6. Fluence to dose equivalent conversion coefficients H'(0.07,0 degrees)/Phi are calculated for positrons of energy ranging between 20 keV and 10 MeV. A comparison between operational dose quantity H'(0.07,0 degrees) and the Local-Skin equivalent Dose shows an overall good agreement between these two quantities, except between 60 keV and 100 key. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:372 / 376
页数:5
相关论文
共 50 条
  • [31] BETA-SKIN DOSE DETERMINATION USING TLDS, MONTE-CARLO CALCULATIONS, AND EXTRAPOLATION CHAMBER
    BENSHACHAR, B
    LEVINE, SH
    HOFFMAN, JM
    HEALTH PHYSICS, 1989, 57 (06): : 917 - 925
  • [32] Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose
    Palm, Å
    Kirov, AS
    LoSasso, T
    MEDICAL PHYSICS, 2004, 31 (12) : 3168 - 3178
  • [33] 3-Dimensional full core neutronic analysis for uranium nitride fuel CANDLE reactor using Monte Carlo MCNP6 code
    Afifah, Maryam
    Su'ud, Zaki
    Trianti, Nuri
    Irwanto, Dwi
    NUCLEAR ENGINEERING AND DESIGN, 2024, 425
  • [34] SELECTED ORGAN DOSE CONVERSION COEFFICIENTS FOR EXTERNAL PHOTONS CALCULATED USING ICRP ADULT VOXEL PHANTOMS AND MONTE CARLO CODE FLUKA
    Patni, H. K.
    Nadar, M. Y.
    Akar, D. K.
    Bhati, S.
    Sarkar, P. K.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 406 - 416
  • [35] Monte Carlo dose calculation of multiple beamlets for IMRT by using a discriminating particle transport and dose tallying approach on the base of MCNP 4B code
    He, T
    Van den Heuvel, F
    MEDICAL PHYSICS, 2002, 29 (06) : 1231 - 1231
  • [36] Monte Carlo calculation of monoenergetic and polyenergetic DgN coefficients for mean glandular dose estimates in mammography using a homogeneous breast model
    Sarno, A.
    Tucciariello, R. M.
    Mettivier, G.
    di Franco, F.
    Russo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [37] Ambient Dose Equivalent Per Therapeutic Dose for 250 Mev Proton Interactions in Tissues using GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S704 - S705
  • [38] Improving Calculations of Electron Eye-lens Operational Dose Coefficients Using the Monte Carlo Codes PENELOPE and MCNP6.2
    Dubeau, Jacques
    Sun, Jiansheng
    Djeffal, Salah
    Ali, Fawaz
    HEALTH PHYSICS, 2024, 126 (05): : 339 - 345
  • [39] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, 36 (11) : 1150 - 1156
  • [40] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Rahman, Ziaur
    Rehman, Shakeel Ur
    Arshed, Waheed
    Mirza, Nasir M.
    Rashid, Abdul
    Zeb, Jahan
    CHINESE PHYSICS C, 2012, 36 (11) : 1150 - 1156