Geometric calibration method based micro-CT system for small-animal imaging

被引:0
|
作者
Hu, Zhanli [1 ,2 ]
Zou, Jing [1 ,2 ]
Gui, Jianbao [1 ,2 ]
Rong, Junyan [1 ,2 ]
Li, Yanming [1 ,2 ]
Zheng, Hairong [1 ,2 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, Shenzhen, Peoples R China
[2] Chinese Acad Sci, Key Lab Biomed Informat & Hlth Engn, Beijing 100864, Peoples R China
关键词
x-ray; micro-CT; geometric calibration; smallanimal imaging; CONE-BEAM TOMOGRAPHY; FLAT-PANEL DETECTOR; MICROTOMOGRAPHY; PARAMETERS; SCANNER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals raised with disease developments or genetic manipulations. Micro-CT is a noninvasive imaging modality used to assess morphology and function in small-animal imaging. Geometric calibration involves the estimation of a set of parameters that describes the geometry of such systems, and is essential for accurate image reconstruction. Noo F et al (2000) have proposed a new analytic method for calibration of x-ray cone-beam scanners that use a circular path for the cone vertex. In this paper, we use this analytic calibration method for the estimation of the geometric parameters of a practical small-animal imaging micro-CT system. We improve calibration phantom of this method in order to make it more suitable for micro-CT system. The overall performance of the micro-CT system is demonstrated in some results of small-animal imaging. The projection images demonstrated that the adopt method is robust and easy to implement with high precision.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Geometric Calibration Based on Identification of Ellipse Parameters of a Micro-CT System for Small-Animal Imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Zhang, Qiyang
    Xia, Dan
    Zheng, Hairong
    [J]. SENSOR LETTERS, 2011, 9 (05) : 1938 - 1942
  • [2] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [3] Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging
    Holdsworth, David W.
    Detombe, Sarah A.
    Chiodo, Chris
    Fricke, Stanley T.
    Drangova, Maria
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [4] Development of novel ultrafast-laser-based micro-CT system for small-animal imaging
    Krol, A
    Kieffer, JC
    Nees, JA
    Chen, LM
    Toth, R
    Hou, BHH
    Kincaid, RE
    Coman, IL
    Chamberlain, CC
    Lipson, ED
    Mourou, GA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1993 - 1996
  • [5] A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Lee, SY
    Cho, MH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24): : 4173 - 4185
  • [6] Geometric Calibration of a Micro-CT System and Performance for Insect Imaging
    Hu, Zhanli
    Gui, Jianbao
    Zou, Jing
    Rong, Junyan
    Zhang, Qiyang
    Zheng, Hairong
    Xia, Dan
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 655 - 660
  • [7] In vivo small-animal imaging using micro-CT and digital subtraction angiography
    Badea, C. T.
    Drangova, M.
    Holdsworth, D. W.
    Johnson, G. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19): : R319 - R350
  • [8] Guest Editor's Introduction: In vivo small-animal imaging using micro-CT
    Brockmann, Marc A.
    [J]. METHODS, 2010, 50 (01) : 1 - 1
  • [9] Ultrafast laser-based micro-CT system for small animal imaging
    Krol, A
    Kieffer, JC
    Nees, J
    Chen, L
    Toth, R
    Hou, B
    Kincaid, RE
    Coman, IL
    Lipson, ED
    Mourou, G
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 265 - 271
  • [10] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39