Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging

被引:0
|
作者
Holdsworth, David W. [1 ,3 ]
Detombe, Sarah A. [1 ,3 ]
Chiodo, Chris [2 ]
Fricke, Stanley T.
Drangova, Maria [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] ASI Instruments Inc, Warren, MI 48089 USA
[3] Childrens Natl Med Ctr, Washington, DC 20010 USA
关键词
small-animal imaging; micro-computed tomography; micro-SPECT; physiological monitoring; animal containment module; CT; REGISTRATION; DESIGN;
D O I
10.1117/12.878855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during preclinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/- 19 HU) and acceptable artifact from high-density components within the AMS (e. g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/- 0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [2] Geometric calibration method based micro-CT system for small-animal imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Li, Yanming
    Zheng, Hairong
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [3] In vivo small-animal imaging using micro-CT and digital subtraction angiography
    Badea, C. T.
    Drangova, M.
    Holdsworth, D. W.
    Johnson, G. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19): : R319 - R350
  • [4] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39
  • [5] Application of micro-CT in small animal imaging
    Schambach, Sebastian J.
    Bag, Simona
    Schilling, Lothar
    Groden, Christoph
    Brockmann, Marc A.
    [J]. METHODS, 2010, 50 (01) : 2 - 13
  • [6] Geometric Calibration Based on Identification of Ellipse Parameters of a Micro-CT System for Small-Animal Imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Zhang, Qiyang
    Xia, Dan
    Zheng, Hairong
    [J]. SENSOR LETTERS, 2011, 9 (05) : 1938 - 1942
  • [7] Development of novel ultrafast-laser-based micro-CT system for small-animal imaging
    Krol, A
    Kieffer, JC
    Nees, JA
    Chen, LM
    Toth, R
    Hou, BHH
    Kincaid, RE
    Coman, IL
    Chamberlain, CC
    Lipson, ED
    Mourou, GA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1993 - 1996
  • [8] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    [J]. PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [9] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 63 - 67
  • [10] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 797 - 801