Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging

被引:0
|
作者
Holdsworth, David W. [1 ,3 ]
Detombe, Sarah A. [1 ,3 ]
Chiodo, Chris [2 ]
Fricke, Stanley T.
Drangova, Maria [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] ASI Instruments Inc, Warren, MI 48089 USA
[3] Childrens Natl Med Ctr, Washington, DC 20010 USA
关键词
small-animal imaging; micro-computed tomography; micro-SPECT; physiological monitoring; animal containment module; CT; REGISTRATION; DESIGN;
D O I
10.1117/12.878855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during preclinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/- 19 HU) and acceptable artifact from high-density components within the AMS (e. g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/- 0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Cardiac Micro-CT Using ECG Gating Signal for Small Animal Imaging
    Guo, Xiaolian
    Tian, Feng
    Tang, Zhiwei
    Hu, Guangshu
    [J]. PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 149 - 152
  • [32] A micro-SPECT/CT system for imaging of AA-amyloidosis in mice
    Gregor, J
    Gleason, S
    Kennel, S
    Paulus, M
    Solomon, A
    Hawkins, P
    Wall, J
    [J]. SMALL ANIMAL SPECT IMAGING, 2005, : 209 - 213
  • [33] Integration of AdaptiSPECT, a small-animal adaptive SPECT imaging system
    Chaix, Cecile
    Kovalsky, Stephen
    Kosmider, Matthew
    Barrett, Harrison H.
    Furenlid, Lars R.
    [J]. MEDICAL APPLICATIONS OF RADIATION DETECTORS III, 2013, 8853
  • [34] Small-animal SPECT dynamic cardiac imaging
    Johnson, Lindsay
    Guerraty, Marie
    Blankemeyer, Eric
    Mankoff, David
    Rader, Daniel
    Metzler, Scott
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [35] Collimator optimization for small animal radiation therapy at a micro-CT
    Felix, Manuela C.
    Glatting, Gerhard
    Giordano, Frank A.
    Brockmann, Marc A.
    Wenz, Frederik
    Fleckenstein, Jens
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (01): : 56 - 64
  • [36] Evaluation of scan strategies for small animal in vivo micro-CT
    Dudak, J.
    Ekendahl, D.
    Judas, L.
    Mrzilkova, J.
    Rubovic, P.
    Zach, P.
    Zemlicka, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [37] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [38] Circular Cone-beam Micro-CT for Small Animal Imaging with Truncated Data
    Cho, Seungryong
    Yu, Lifeng
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2889 - 2891
  • [39] Small-animal SPECT and SPECT/CT: application in cardiovascular research
    Golestani, Reza
    Wu, Chao
    Tio, Rene A.
    Zeebregts, Clark J.
    Petrov, Artiom D.
    Beekman, Freek J.
    Dierckx, Rudi A. J. O.
    Boersma, Hendrikus H.
    Slart, Riemer H. J. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1766 - 1777
  • [40] Small-animal SPECT and SPECT/CT: application in cardiovascular research
    Reza Golestani
    Chao Wu
    René A. Tio
    Clark J. Zeebregts
    Artiom D. Petrov
    Freek J. Beekman
    Rudi A. J. O. Dierckx
    Hendrikus H. Boersma
    Riemer H. J. A. Slart
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1766 - 1777