Collimator optimization for small animal radiation therapy at a micro-CT

被引:2
|
作者
Felix, Manuela C. [1 ,2 ]
Glatting, Gerhard [1 ]
Giordano, Frank A. [2 ]
Brockmann, Marc A. [3 ,4 ]
Wenz, Frederik [2 ]
Fleckenstein, Jens [2 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Med Radiat Phys Protect, Mannheim, Germany
[2] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Radiat Oncol, Mannheim, Germany
[3] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Neuroradiol, Mannheim, Germany
[4] Univ Med Ctr Mainz, Dept Neuroradiol, Mainz, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2017年 / 27卷 / 01期
关键词
Small animal radiation therapy; collimator design; small field dosimetry; kV-dosimetry; film dosimetry; RADIOCHROMIC FILM DOSIMETRY; RADIOTHERAPY; SYSTEM;
D O I
10.1016/j.zemedi.2016.05.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. Material and methods: An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. Results: As expected, the shorter SSD of the W collimators resulted in a (4.5 +/- 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 +/- 0.2) for the Fe- and (4.5 +/- 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Conclusion: Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper penumbra. The dosimetry of small kilovoltage beams with Gafchromic EBT3 films in a water phantom has proven successful.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 50 条
  • [1] Small animal micro-CT colonography
    Durkee, Benjamin Y.
    Weichert, Jamey P.
    Halberg, Richard B.
    [J]. METHODS, 2010, 50 (01) : 36 - 41
  • [2] Development of GE EXplore CT 120 Micro-CT for Small Animal Radiotherapy with an In-Bore Collimator
    Jensen, M.
    Chen, J.
    Holdsworth, D.
    Drangova, M.
    Van Sas, F.
    Wong, E.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39
  • [4] Application of micro-CT in small animal imaging
    Schambach, Sebastian J.
    Bag, Simona
    Schilling, Lothar
    Groden, Christoph
    Brockmann, Marc A.
    [J]. METHODS, 2010, 50 (01) : 2 - 13
  • [5] Micro-CT system for Small animal irradiation: Modification and Characterization
    Felix, M.
    Fleckenstein, J.
    Kirschner, S.
    Brockmann, M. A.
    Wenz, F.
    Glatting, G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 146 - 146
  • [6] Evaluation of scan strategies for small animal in vivo micro-CT
    Dudak, J.
    Ekendahl, D.
    Judas, L.
    Mrzilkova, J.
    Rubovic, P.
    Zach, P.
    Zemlicka, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [7] Preliminary studies of a micro-CT for a combined small animal PET/CT scanner
    Khodaverdi, M
    Pauly, F
    Weber, S
    Schröder, G
    Ziemons, K
    Sievering, R
    Halling, H
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1605 - 1606
  • [8] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [9] Evaluation of the radiation dose in micro-CT with optimization of the scan protocol
    Willekens, Inneke
    Buls, Nico
    Lahoutte, Tony
    Baeyens, Luc
    Vanhove, Christian
    Caveliers, Vicky
    Deklerck, Rudi
    Bossuyt, Axel
    de Mey, Johan
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2010, 5 (04) : 201 - 207
  • [10] Optimization of a Microbeam Collimator for Use on the Small Animal Radiation Research Platform
    Esplen, N.
    Johnstone, C.
    Chergui, L.
    Bazalova-Carter, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E533 - E533