Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging

被引:0
|
作者
Holdsworth, David W. [1 ,3 ]
Detombe, Sarah A. [1 ,3 ]
Chiodo, Chris [2 ]
Fricke, Stanley T.
Drangova, Maria [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] ASI Instruments Inc, Warren, MI 48089 USA
[3] Childrens Natl Med Ctr, Washington, DC 20010 USA
关键词
small-animal imaging; micro-computed tomography; micro-SPECT; physiological monitoring; animal containment module; CT; REGISTRATION; DESIGN;
D O I
10.1117/12.878855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during preclinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/- 19 HU) and acceptable artifact from high-density components within the AMS (e. g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/- 0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Quantitative imaging with the micro-pet small-animal pet tomograph
    Vaska, Paul
    Rubins, Daniel J.
    Alexoff, David L.
    Schiffert, Wynne K.
    [J]. INTERNATIONAL REVIEW OF NEUROBIOLOGY, VOL 73, 2006, 73 : 191 - +
  • [42] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Keiichi Magota
    Naoki Kubo
    Yuji Kuge
    Ken-ichi Nishijima
    Songji Zhao
    Nagara Tamaki
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 742 - 752
  • [43] Development of a Germanium Small-Animal SPECT System
    Johnson, Lindsay C.
    Ovchinnikov, Oleg
    Shokouhi, Sepideh
    Peterson, Todd E.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 2036 - 2042
  • [44] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Magota, Keiichi
    Kubo, Naoki
    Kuge, Yuji
    Nishijima, Ken-ichi
    Zhao, Songji
    Tamaki, Nagara
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (04) : 742 - 752
  • [45] SPECT low-field MRI system for small-animal imaging
    Goetz, Christian
    Breton, Elodie
    Choquet, Philippe
    Israel-Jost, Vincent
    Constantinesco, Andre
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (01) : 88 - 93
  • [46] Performance evaluation of a micro-CT system for laboratory animal imaging with iterative reconstruction capabilities
    Muller, Florence M.
    Vanhove, Christian
    Vandeghinste, Bert
    Vandenberghe, Stefaan
    [J]. MEDICAL PHYSICS, 2022, 49 (05) : 3121 - 3133
  • [47] Preliminary studies of a micro-CT for a combined small animal PET/CT scanner
    Khodaverdi, M
    Pauly, F
    Weber, S
    Schröder, G
    Ziemons, K
    Sievering, R
    Halling, H
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1605 - 1606
  • [48] Micro-CT system for small animal imaging with ultrafast laser-based x-ray source
    Krol, A
    Kieffer, JC
    Chen, L
    Toth, R
    Coman, LL
    Lipson, ED
    Kincaid, RE
    Chamberlain, CC
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1516 - 1519
  • [49] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (01) : 74 - 79
  • [50] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1840 - 1844