Ultrafast laser-based micro-CT system for small animal imaging

被引:3
|
作者
Krol, A [1 ]
Kieffer, JC [1 ]
Nees, J [1 ]
Chen, L [1 ]
Toth, R [1 ]
Hou, B [1 ]
Kincaid, RE [1 ]
Coman, IL [1 ]
Lipson, ED [1 ]
Mourou, G [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
关键词
ultrafast laser-based X-ray source; micro-CT; dual energy CT;
D O I
10.1117/12.536190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated ultrafast laser-based x-ray (ULX) source as an attractive alternative to a microfocal x-ray tube used in micro-CT systems. The laser pulse duration was in the 30 fs -200 fs range, the repetition rate in the 10 Hz - 1 kHz range. A number of solid targets including Ge, Mo, Rh, Ag, Sn, Ba, La, Nd with matching filters was used. We optimized conditions for x-rays generation and measured: x-ray spectra, conversion efficiency (from laser light to x-rays), x-ray fluence, effective x-ray focal spot size and spatial resolution, contrast resolution and radiation dose. Good quality projection images of small animals in single- and dual-energy mode were obtained. ULX generates narrow x-ray spectra that consist mainly of characteristic lines that can be easily tailored (by changing laser beam target) to the imaging task, (e.g. to maximize contrast while minimizing radiation dose). X-ray fluence can exceed fluence produced by conventional microfocal tube with 10 mum focal-spot hence allowing for faster scans with very high spatial resolution. Changing the laser target, and thus matching the characteristic emission lines with the investigated animal's thickness and composition, cm be done quickly and easily. Using narrow emission lines for imaging, instead of broad bremsstrahlung, offers superior dose utilization and limits beam-hardening effects. Employing two narrow emission lines-above and below the absorption edge of a contrast agent-in quick succession allows dual-energy-subtraction micro-CT for imaging with a contrast medium. Dual-energy-subtraction is not practical with a microfocal tube. Compact, robust, ultrafast lasers are commercially available, and their characteristics are rapidly improving. We plan to construct a prototype in vivo ultrafast laser-based micro-CT system.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 50 条
  • [1] Micro-CT system for small animal imaging with ultrafast laser-based x-ray source
    Krol, A
    Kieffer, JC
    Chen, L
    Toth, R
    Coman, LL
    Lipson, ED
    Kincaid, RE
    Chamberlain, CC
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1516 - 1519
  • [2] Development of novel ultrafast-laser-based micro-CT system for small-animal imaging
    Krol, A
    Kieffer, JC
    Nees, JA
    Chen, LM
    Toth, R
    Hou, BHH
    Kincaid, RE
    Coman, IL
    Chamberlain, CC
    Lipson, ED
    Mourou, GA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1993 - 1996
  • [3] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39
  • [4] Application of micro-CT in small animal imaging
    Schambach, Sebastian J.
    Bag, Simona
    Schilling, Lothar
    Groden, Christoph
    Brockmann, Marc A.
    [J]. METHODS, 2010, 50 (01) : 2 - 13
  • [5] Mean absorbed dose to mouse in micro-CT imaging with an ultrafast laser-based x-ray source
    Krol, Andrzej
    Ye, Hongwei
    Kincaid, Russell
    Boone, John
    Servol, Marina
    Kieffer, Jean-Claude
    Nesterets, Yakov
    Gureyev, Tim
    Stevenson, Andrew
    Wilkins, Steve
    Lipson, Edward
    Toth, Remy
    Pogany, Andrew
    Coman, Ioana
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [6] Geometric calibration method based micro-CT system for small-animal imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Li, Yanming
    Zheng, Hairong
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [7] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    [J]. PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [8] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [9] Design an development of a high performance micro-CT system for small animal imaging
    Lage, E.
    Vaquero, J. J.
    Redondo, S.
    Abella, M.
    Tapias, G.
    Udias, A.
    Desco, M.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3549 - 3552
  • [10] Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging
    Holdsworth, David W.
    Detombe, Sarah A.
    Chiodo, Chris
    Fricke, Stanley T.
    Drangova, Maria
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965