A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging

被引:96
|
作者
Lee, SC [1 ]
Kim, HK [1 ]
Chun, IK [1 ]
Cho, MH [1 ]
Lee, SY [1 ]
Cho, MH [1 ]
机构
[1] Kyung Hee Univ, Grad Sch EW Med Sci, Yongin 449701, Kyungki, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 24期
关键词
D O I
10.1088/0031-9155/48/24/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm(2), a microfocus x-ray source, a rotational subject holder and a parallel data processing system. The flat-panel detector is based on a matrix-addressed photodiode array fabricated by a CMOS (complementary metal-oxide semiconductor) process coupled to a CsI:TI (thallium-doped caesium iodide) scintillator as an x-ray-to-light converter. Principal imaging performances of the micro-CT system have been evaluated in terms of image uniformity, voxel noise and spatial resolution. It has been found that the irnage non-uniformity mainly comes from the structural non-uniform sensitivity pattern of the flat-panel detector and the voxel noise is about 48 CT numbers at the voxel size of 100 x 100 x 200 mum(3) and the air kerma of 286 mGy. When the magnification ratio is 2, the spatial resolution of the micro-CT system is about 14 1p/mm (line pairs per millimetre) that is almost determined by the flat-panel detector showing about 7 1p/mm resolving power. Through low-contrast phantom imaging studies, the minimum resolvable contrast has been found to be less than 36 CT numbers at the air kerma of 95 mGy. Some laboratory rat imaging results are presented.
引用
收藏
页码:4173 / 4185
页数:13
相关论文
共 50 条
  • [1] Performance evaluation of a flat-panel detector-based microtomography system for small-animal imaging
    Kim, HK
    Lee, SC
    Chun, IK
    Cho, MH
    Cho, MH
    Lee, SY
    Joo, KS
    Cho, GS
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2108 - 2113
  • [2] Use of a flat-panel detector for microtomography: A feasibility study for small-animal imaging
    Kim, HK
    Lee, SC
    Cho, MH
    Lee, SY
    Cho, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 193 - 198
  • [3] Geometric calibration method based micro-CT system for small-animal imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Li, Yanming
    Zheng, Hairong
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [4] Comparative Study of Two Flat-Panel X-Ray Detectors Applied to Small-Animal Imaging Cone-Beam Micro-CT
    Sisniega, Alejandro
    Jose Vaquero, Juan
    Lage, Eduardo
    de Carlos, Alvaro
    Villena, Jose L.
    Abella, Monica
    Vidal, Irina
    Tapias, Gustavo
    Carlos Antoranz, Jose
    Desco, Manuel
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3111 - +
  • [5] A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system
    Vedantham, Srinivasan
    Shrestha, Suman
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [6] Prototype Flat-panel Based μCT System for Small Animal Studies
    Fang, Zheng
    Gong, Hui
    Zhang, Tianxu
    [J]. PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 328 - +
  • [7] Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging
    Holdsworth, David W.
    Detombe, Sarah A.
    Chiodo, Chris
    Fricke, Stanley T.
    Drangova, Maria
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [8] Geometric Calibration Based on Identification of Ellipse Parameters of a Micro-CT System for Small-Animal Imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Zhang, Qiyang
    Xia, Dan
    Zheng, Hairong
    [J]. SENSOR LETTERS, 2011, 9 (05) : 1938 - 1942
  • [9] Development of novel ultrafast-laser-based micro-CT system for small-animal imaging
    Krol, A
    Kieffer, JC
    Nees, JA
    Chen, LM
    Toth, R
    Hou, BHH
    Kincaid, RE
    Coman, IL
    Chamberlain, CC
    Lipson, ED
    Mourou, GA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1993 - 1996
  • [10] Motion gated small animal imaging with a flat-panel CT
    Grasruck, M.
    Bartling, S.
    Dinkel, J.
    Kiessling, F.
    Semmler, W.
    Stierstorfer, K.
    Schmidt, B.
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913