Motion gated small animal imaging with a flat-panel CT

被引:1
|
作者
Grasruck, M. [1 ]
Bartling, S. [2 ]
Dinkel, J. [2 ]
Kiessling, F. [2 ]
Semmler, W. [2 ]
Stierstorfer, K. [1 ]
Schmidt, B. [1 ]
机构
[1] Siemens Healthcare, D-91294 Forchheim, Germany
[2] German Canc Res Ctr, D-69120 Heidelberg, Germany
关键词
flat panel CT; motion gated reconstruction; small animal imaging; volume CT;
D O I
10.1117/12.769386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small animal CT gains increasing interest in preclinical research. However, physiological motion compensation like in clinical CT has seldom been employed so far. We present different methods of retrospective motion correction for small animal imaging despite their high respiratory and heart rate. Beside respiratory gating alone the combination of respiratory and simultaneous cardiac gating is shown. In vivo data are acquired with an experimental flat-panel based CT scanner* (Siemens Healthcare, Forchheim Germany). Whole mice or rats fit in the available FOV of 25 * 25 * 4 cm(3), while acquisition rate is 100fps. Extrinsic gating is realized by tracing the physiological motion from a small animal monitoring system with a pneumatic pillow for respiratory motion and ECG for heart motion. At the alternative intrinsic method, the lung motion is directly correlated to the movement of the center of gravity in the acquired projection data. As an advantage of the second method the even low preparation effort per scan is reduced. As long as the rotation time of the gantry is far below the cycle time of heart or the lung a multi-segment reconstruction is used in both methods. Motion artifacts are largely suppressed after gating. While in non gated images, the diaphragm, heart contours, bronchi and lung vessels are already visible, they are more sharply defined in the gated datasets. Four-dimensional assessment of lung motion is possible and lung volume in several phases such as peak inspiration and expiration could be segmented, quantified and compared.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging
    Greschus, S
    Kiessling, F
    Lichy, MP
    Moll, J
    Mueller, MM
    Savai, R
    Rose, F
    Ruppert, C
    Günther, A
    Luecke, M
    Fusenig, NE
    Semmler, W
    Traupe, H
    [J]. NEOPLASIA, 2005, 7 (08): : 730 - 740
  • [2] Small Animal Imaging with Micro, Flat-panel and Clinical CT-Scanners: An Applicability Analysis\
    Stiller, W.
    Kiessling, F.
    Semmler, W.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 13, 2009, 25 (13): : 88 - +
  • [3] Prototype Flat-panel Based μCT System for Small Animal Studies
    Fang, Zheng
    Gong, Hui
    Zhang, Tianxu
    [J]. PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 328 - +
  • [4] The use of flat-panel detectors for CT imaging
    Kalender, WA
    [J]. RADIOLOGE, 2003, 43 (05): : 379 - 387
  • [5] A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Lee, SY
    Cho, MH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24): : 4173 - 4185
  • [6] Use of a flat-panel detector for microtomography: A feasibility study for small-animal imaging
    Kim, HK
    Lee, SC
    Cho, MH
    Lee, SY
    Cho, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 193 - 198
  • [7] Performance evaluation of a flat-panel detector-based microtomography system for small-animal imaging
    Kim, HK
    Lee, SC
    Chun, IK
    Cho, MH
    Cho, MH
    Lee, SY
    Joo, KS
    Cho, GS
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2108 - 2113
  • [8] Simulation of Motion Artifacts in Offset Flat-Panel Cone-Beam CT
    Hansis, Eberhard
    Shao, Lingxiong
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2471 - 2475
  • [9] Feasibility of flat-panel volumetric computed tomography (fpVCT) in experimental small animal imaging of osteoporosis - initial experience
    Valencia, R.
    Stuermer, E. K.
    Dullin, C.
    Herrmann, K. R.
    Kluever, I.
    Zaroban, A.
    Sehmisch, S.
    Funke, M.
    Knollmann, F.
    [J]. RADIOLOGE, 2006, 46 (10): : 893 - 899
  • [10] Musculoskeletal applications of flat-panel volume CT
    Benjamin Reichardt
    Ammar Sarwar
    Soenke H. Bartling
    Arnold Cheung
    Michael Grasruck
    Christianne Leidecker
    Miriam A. Bredella
    Thomas J. Brady
    Rajiv Gupta
    [J]. Skeletal Radiology, 2008, 37 : 1069 - 1076