A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures

被引:37
|
作者
Wolf, Jonathon C.
Weil, Wayne M.
Hanel, Douglas P.
Trumble, Thomas E.
机构
[1] Univ Washington, Harborview Med Ctr, Hand Ctr, Seattle, WA 98104 USA
[2] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
关键词
biomechanics; external fixation; internal fixation; locking plate; radius fracture;
D O I
10.1016/j.jhsa.2006.09.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the biomechanic stability of distal radius fracture fixation with a new internal radiocarpal-spanning 2.4-mm locking plate, which acts as an internal distal radius fixator, versus a standard distal radius external fixator. The number of locking screws necessary for adequate fracture fixation was also assessed. Methods: Ten cadaveric specimens were mounted in a loading fixture with cables attached to the 2 flexor and 3 extensor wrist tendons. A 1-cm osteotomy was created to simulate an unstable distal radius fracture. The radiocarpal-spanning locking plate was fixed to the radius and index metacarpal with 4 screws proximally and 4 distally. The specimen was incrementally loaded through the tendons. Motion at the fracture site was determined. Screws were sequentially removed from the construct, the specimen was again incrementally loaded, and fracture motion was measured. The fixation was then changed to an external fixator, and the loading tests were repeated. Results: Fracture fixation with the radiocarpal-spanning 2.4-mm locking plate was significantly more stable with 4 screws proximally and 4 screws distally (4 X 4) and with the 3 X 3 configuration than with the external fixator in both flexion and extension. The 4 X 4 screw configuration was not significantly different from the 3 X 3 screw configuration. The 4 X 4 screw configuration was significantly more stable than the 2 X 2 and 1 X 1 screw configurations in both flexion and extension. All internal fixator configurations and the external fixator showed more fracture displacement at increasingly higher loads. Conclusions: Fracture fixation with the new internal radiocarpal-spanning 2.4-mm locking plate is more stable than with a standard distal radius external fixator. Only three 2.4-mm locking screws proximally and three 2.4-mm locking screws distally are required for adequate fixation of the locking spanning plate.
引用
收藏
页码:1578 / 1586
页数:9
相关论文
共 50 条
  • [1] Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
    Musgrave, DS
    Idler, RS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 743 - 749
  • [2] Dorsal and Volar 2.4-mm Locking Plate Fixation for AO Type C3 Dorsally Comminuted Distal Radius Fractures
    Chou, Ying-Chao
    Chen, Alvin Chao-Yu
    Chen, Chun-Ying
    Hsu, Yung-Heng
    Wu, Chi-Chuan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 974 - 981
  • [3] Dorsal approach and internal fixation of impacted intra-articular distal radius fractures with 2.4 mm locking plates
    De Smet, A.
    Lamouille, J.
    Vostrel, P.
    Loret, M.
    Hoffmeyer, P.
    Beaulieu, J. -Y.
    HAND SURGERY & REHABILITATION, 2016, 35 (03): : 203 - 209
  • [4] Plate fixation with locking screw for distal fractures of the radius
    Cognet, J. -M.
    Geanah, A.
    Marsal, C.
    Kadoch, V.
    Gouzou, S.
    Simon, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (07): : 663 - 672
  • [5] Biomechanical comparison of an internal spanning wrist plate and an external fixator in a human cadaveric model of distal radius fractures.
    Wolf, JC
    Weil, WM
    Hanel, DP
    Trumble, TE
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S169 - S169
  • [6] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960
  • [7] External Fixation Versus "π" Plate for Distal Radius Fractures
    Kateros, Konstantinos
    Macheras, George
    Galanakos, Spyros P.
    Sofianos, Ioannis
    Papakostas, Ioannis
    Papadakis, Stamatios A.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01): : 166 - 172
  • [8] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [9] Combined internal and external fixation of distal radius fractures
    McAuliffe, JA
    HAND CLINICS, 2005, 21 (03) : 395 - +
  • [10] Volar locking plate versus external fixation in distal radius fractures: A meta-analysis
    Maccagnano, Giuseppe
    Noia, Giovanni
    Vicenti, Giovanni
    Baglioni, Marco
    Masciale, Maria Rosa
    Cassano, Giuseppe Danilo
    Vitiello, Raffaele
    Moretti, Biagio
    Pesce, Vito
    ORTHOPEDIC REVIEWS, 2021, 13 (01)