A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures

被引:37
|
作者
Wolf, Jonathon C.
Weil, Wayne M.
Hanel, Douglas P.
Trumble, Thomas E.
机构
[1] Univ Washington, Harborview Med Ctr, Hand Ctr, Seattle, WA 98104 USA
[2] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
关键词
biomechanics; external fixation; internal fixation; locking plate; radius fracture;
D O I
10.1016/j.jhsa.2006.09.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the biomechanic stability of distal radius fracture fixation with a new internal radiocarpal-spanning 2.4-mm locking plate, which acts as an internal distal radius fixator, versus a standard distal radius external fixator. The number of locking screws necessary for adequate fracture fixation was also assessed. Methods: Ten cadaveric specimens were mounted in a loading fixture with cables attached to the 2 flexor and 3 extensor wrist tendons. A 1-cm osteotomy was created to simulate an unstable distal radius fracture. The radiocarpal-spanning locking plate was fixed to the radius and index metacarpal with 4 screws proximally and 4 distally. The specimen was incrementally loaded through the tendons. Motion at the fracture site was determined. Screws were sequentially removed from the construct, the specimen was again incrementally loaded, and fracture motion was measured. The fixation was then changed to an external fixator, and the loading tests were repeated. Results: Fracture fixation with the radiocarpal-spanning 2.4-mm locking plate was significantly more stable with 4 screws proximally and 4 screws distally (4 X 4) and with the 3 X 3 configuration than with the external fixator in both flexion and extension. The 4 X 4 screw configuration was not significantly different from the 3 X 3 screw configuration. The 4 X 4 screw configuration was significantly more stable than the 2 X 2 and 1 X 1 screw configurations in both flexion and extension. All internal fixator configurations and the external fixator showed more fracture displacement at increasingly higher loads. Conclusions: Fracture fixation with the new internal radiocarpal-spanning 2.4-mm locking plate is more stable than with a standard distal radius external fixator. Only three 2.4-mm locking screws proximally and three 2.4-mm locking screws distally are required for adequate fixation of the locking spanning plate.
引用
收藏
页码:1578 / 1586
页数:9
相关论文
共 50 条
  • [31] Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures
    Natoli, R. M.
    Baer, M. R.
    Bednar, M. S.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (03) : 339 - 343
  • [32] Volar locking plate fixation for distal radius fractures: Does age affect outcome?
    Ezzat, Ahmed
    Baliga, Santosh
    Carnegie, Carol
    Johnstone, Alan
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (02) : 76 - 80
  • [33] Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    Wilkens, Kenneth J.
    Curtiss, Shane
    Lee, Mark A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 624 - 628
  • [34] Recovery of Wrist Function after Volar Locking Plate Fixation for Distal Radius Fractures
    Takeuchi, Naohide
    Hotokezaka, Shunsuke
    Okada, Takamitsu
    Yuge, Hidehiko
    Mae, Takao
    Iwamoto, Yukihide
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02): : 199 - 206
  • [35] Residual wrist pain after volar locking plate fixation of distal radius fractures
    Kurimoto, Shigeru
    Tatebe, Masahiro
    Shinohara, Takaaki
    Arai, Tetsuya
    Hirata, Hitoshi
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (05): : 603 - 610
  • [36] Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization
    Duprat, Andre
    Diaz, Juan Jose Hidalgo
    Vernet, Paul
    Gouzou, Stephanie
    Facca, Sybille
    Igeta, Yuka
    Liverneaux, Philippe
    JOURNAL OF WRIST SURGERY, 2018, 7 (03) : 237 - 242
  • [37] LOCKING PALMAR PLATE FIXATION FOR DORSALLY DISPLACED FRACTURES OF THE DISTAL RADIUS: A PRELIMINARY REPORT
    Moriya, Koji
    Saito, Hidehiko
    Takahashi, Yuji
    Ohi, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (03): : 363 - 369
  • [38] Comparison of different locking plate fixation methods in distal tibia fractures
    Piatkowski, Krzysztof
    Piekarczyk, Piotr
    Kwiatkowski, Krzysztof
    Przybycien, Mateusz
    Chwedczuk, Bartlomiej
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2245 - 2251
  • [39] Comparison of different locking plate fixation methods in distal tibia fractures
    Krzysztof Piątkowski
    Piotr Piekarczyk
    Krzysztof Kwiatkowski
    Mateusz Przybycień
    Bartłomiej Chwedczuk
    International Orthopaedics, 2015, 39 : 2245 - 2251
  • [40] Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients
    Wang, Minghui
    Wang, Bin
    Wang, Xiuhui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 1185 - 1191