A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures

被引:37
|
作者
Wolf, Jonathon C.
Weil, Wayne M.
Hanel, Douglas P.
Trumble, Thomas E.
机构
[1] Univ Washington, Harborview Med Ctr, Hand Ctr, Seattle, WA 98104 USA
[2] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
来源
关键词
biomechanics; external fixation; internal fixation; locking plate; radius fracture;
D O I
10.1016/j.jhsa.2006.09.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the biomechanic stability of distal radius fracture fixation with a new internal radiocarpal-spanning 2.4-mm locking plate, which acts as an internal distal radius fixator, versus a standard distal radius external fixator. The number of locking screws necessary for adequate fracture fixation was also assessed. Methods: Ten cadaveric specimens were mounted in a loading fixture with cables attached to the 2 flexor and 3 extensor wrist tendons. A 1-cm osteotomy was created to simulate an unstable distal radius fracture. The radiocarpal-spanning locking plate was fixed to the radius and index metacarpal with 4 screws proximally and 4 distally. The specimen was incrementally loaded through the tendons. Motion at the fracture site was determined. Screws were sequentially removed from the construct, the specimen was again incrementally loaded, and fracture motion was measured. The fixation was then changed to an external fixator, and the loading tests were repeated. Results: Fracture fixation with the radiocarpal-spanning 2.4-mm locking plate was significantly more stable with 4 screws proximally and 4 screws distally (4 X 4) and with the 3 X 3 configuration than with the external fixator in both flexion and extension. The 4 X 4 screw configuration was not significantly different from the 3 X 3 screw configuration. The 4 X 4 screw configuration was significantly more stable than the 2 X 2 and 1 X 1 screw configurations in both flexion and extension. All internal fixator configurations and the external fixator showed more fracture displacement at increasingly higher loads. Conclusions: Fracture fixation with the new internal radiocarpal-spanning 2.4-mm locking plate is more stable than with a standard distal radius external fixator. Only three 2.4-mm locking screws proximally and three 2.4-mm locking screws distally are required for adequate fixation of the locking spanning plate.
引用
收藏
页码:1578 / 1586
页数:9
相关论文
共 50 条
  • [21] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [22] Dorsal 2.4 mm locking plate fixation of intra-articular fractures with articular impaction and dorsal displacement of the distal radius: a propos of 21 cases
    De Smet, Alexander
    Kampfen, Stephane
    Van Aaken, Jan
    Beaulieu, Jean-Yves
    SWISS MEDICAL WEEKLY, 2011, 141 : 23S - 23S
  • [23] Distal Radius Fractures in a Functional Quadruped: Spanning Bridge Plate Fixation of the Wrist
    Tinsley, Brian A.
    Ilyas, Asif M.
    HAND CLINICS, 2018, 34 (01) : 113 - +
  • [24] Outcomes of Primary Volar Locking Plate Fixation of Open Distal Radius Fractures
    Joo, Min Su
    Kang, Hong Je
    Yu, Hyun Kyu
    Lee, Jae Sung
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (03): : 517 - 523
  • [25] A Randomized Comparison of Volar Plate and External Fixation for Intra-Articular Distal Radius Fractures
    Roh, Young Hak
    Lee, Beom Koo
    Baek, Jong Ryoon
    Noh, Jung Ho
    Gong, Hyun Sik
    Baek, Goo Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 34 - 41
  • [26] Comparison of palmar locking plate and K-wire augmented external fixation for intra-articular and comminuted distal radius fractures
    Gereli, Arel
    Nalbantoglu, Ufuk
    Kocaoglu, Baris
    Turkmen, Metin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (03) : 212 - 219
  • [27] Results of internal fixation for unstable distal radius fracture with palmar locking plate
    Windolf, J.
    Hakimi, M.
    Schaedel-Hoepfner, M.
    TRAUMA UND BERUFSKRANKHEIT, 2008, 10 : 236 - 240
  • [28] Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures
    Nalbantoglu, Ufuk
    Gereli, Arel
    Ucar, Yavuz
    Turkmen, Metin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (05) : 365 - 372
  • [29] TREATMENT WITH OR WITHOUT INTERNAL FIXATION FOR ULNAR STYLOID BASE FRACTURES ACCOMPANIED BY DISTAL RADIUS FRACTURES FIXED WITH VOLAR LOCKING PLATE
    Zenke, Yukichi
    Sakai, Akinori
    Oshige, Toshihisa
    Moritani, Shiro
    Nakamura, Toshitaka
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2012, 17 (02): : 181 - 190
  • [30] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13