Purpose: To compare the biomechanic stability of distal radius fracture fixation with a new internal radiocarpal-spanning 2.4-mm locking plate, which acts as an internal distal radius fixator, versus a standard distal radius external fixator. The number of locking screws necessary for adequate fracture fixation was also assessed. Methods: Ten cadaveric specimens were mounted in a loading fixture with cables attached to the 2 flexor and 3 extensor wrist tendons. A 1-cm osteotomy was created to simulate an unstable distal radius fracture. The radiocarpal-spanning locking plate was fixed to the radius and index metacarpal with 4 screws proximally and 4 distally. The specimen was incrementally loaded through the tendons. Motion at the fracture site was determined. Screws were sequentially removed from the construct, the specimen was again incrementally loaded, and fracture motion was measured. The fixation was then changed to an external fixator, and the loading tests were repeated. Results: Fracture fixation with the radiocarpal-spanning 2.4-mm locking plate was significantly more stable with 4 screws proximally and 4 screws distally (4 X 4) and with the 3 X 3 configuration than with the external fixator in both flexion and extension. The 4 X 4 screw configuration was not significantly different from the 3 X 3 screw configuration. The 4 X 4 screw configuration was significantly more stable than the 2 X 2 and 1 X 1 screw configurations in both flexion and extension. All internal fixator configurations and the external fixator showed more fracture displacement at increasingly higher loads. Conclusions: Fracture fixation with the new internal radiocarpal-spanning 2.4-mm locking plate is more stable than with a standard distal radius external fixator. Only three 2.4-mm locking screws proximally and three 2.4-mm locking screws distally are required for adequate fixation of the locking spanning plate.
引用
收藏
页码:1578 / 1586
页数:9
相关论文
共 50 条
  • [41] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [42] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Fu, Qiang
    Zhu, Lei
    Yang, Peng
    Chen, Aimin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (06) : 602 - 610
  • [43] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Qiang Fu
    Lei Zhu
    Peng Yang
    Aimin Chen
    Indian Journal of Orthopaedics, 2018, 52 : 602 - 610
  • [44] Mechanical comparison of fixed angle locking volar plate and K-wire fixation of distal radius fractures
    Rigo, I. Z.
    Fosse, O. A. K.
    PROCEEDINGS OF THE 10TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR SURGERY OF THE HAND & 7TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR HAND THERAPY, 2007, : 343 - +
  • [45] Comparison of angle stable plate fixation approaches for distal radius fractures
    Matschke, S.
    Wentzensen, A.
    Ring, D.
    Marent-Huber, M.
    Audige, L.
    Jupiter, J. B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (04): : 385 - 392
  • [46] Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis
    Peng, Fei
    Liu, Yuan-xiang
    Wan, Zhen-yu
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 158 - 167
  • [47] The spanning plate as an internal fixator in complex distal radius fractures: a prospective cohort study
    Rémy Liechti
    Reto Babst
    Urs Hug
    Björn-Christian Link
    Bryan J. M. van de Wall
    Matthias Knobe
    Frank J. P. Beeres
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 2369 - 2377
  • [48] Complication Rate Comparing Variable Angle Distal Locking Plate to Fixed Angle Plate Fixation of Distal Radius Fractures
    Mehrzad, Raman
    Kim, David C.
    ANNALS OF PLASTIC SURGERY, 2016, 77 (06) : 623 - 625
  • [49] The spanning plate as an internal fixator in complex distal radius fractures: a prospective cohort study
    Liechti, Remy
    Babst, Reto
    Hug, Urs
    Link, Bjorn-Christian
    van de Wall, Bryan J. M.
    Knobe, Matthias
    Beeres, Frank J. P.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (03) : 2369 - 2377
  • [50] Prospective Randomised Study of Intra-Articular Fractures of the Distal Radius: Comparison Between External Fixation and Plate Fixation
    Xu, Germaine G. Q.
    Chan, Siew Pang
    Puhaindran, Mark Edward
    Chew, Winston Y. C.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2009, 38 (07) : 600 - 605