Plate fixation with locking screw for distal fractures of the radius

被引:0
|
作者
Cognet, J. -M. [1 ]
Geanah, A. [1 ]
Marsal, C. [1 ]
Kadoch, V. [1 ]
Gouzou, S. [1 ]
Simon, P. [1 ]
机构
[1] Hop Hautepierre, Dept Chirurg Orthoped & Traumatol, Unite Chirurg Membre Super, CHU Hautepierre, F-67098 Strasbourg, France
关键词
fracture; distal fracture of the radius; plate fixation with locking screw;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Fractures of the distal radius are common. No one implant has demonstrated superior efficacy in terms of maintaining the reduction over time. We report our experience with plate fixation using a locking screw. Material and methods Between September 2003 and June 2004, 67 displaced fractures of the distal radius were treated by plate fixation using the LCP-DRP 2.4 (Synthes(R)). Three different plates (anterior, posterior, and external) were used. The patients wore a removable anatomic brace for three weeks. Self-controlled rehabilitation exercises began directly after surgery with mobilization of the digital chains. The Fernandez, Castaing and AO classifications were noted. Ulnar variance, anteversion of the radial glenoid, radial slope and the alpha angle were measured intraoperatively and at last follow-up to assess maintenance of reduction over time. The DASH test and Green and O'Brien and PRWE scores were used to assess clinical outcome. Results Mean follow-up was eight months. Mean age was 55.8 years. Eight patients were lost to follow-up. The analysis included 59 patients who could respond to the questionnaires. Bone healing was achieved at six weeks. There were no cases of secondary displacement nor loss of reduction. The Green and O'Brien score was good or very good for 85%. The mean DASH was 20.6 and the mean PRWE 32.8. Discussion The appropriate fixation method for distal fractures of the radius remains a controversial issue, leading to a variety of materials and fixation methods. Primary stability achieved with the locking screw in a plate enables early mobilization associated with more rapid recovery of function. The absence of secondary displacement, irrespective of the quality of the underlying bone enabled us to achieve equivalent results in young patients and older patients with osteoporotic bone. This study also confirmed the preference for the anterior approach, irrespective of the direction of the displacement. To date, no other material has enabled equivalent results. This is a major achievement in terms of fixation stability.
引用
收藏
页码:663 / 672
页数:10
相关论文
共 50 条
  • [1] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    [J]. BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [2] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [3] Complications after volar locking plate fixation of distal radius fractures
    Johnson, N. A.
    Cutler, L.
    Dias, J. J.
    Ullah, A. S.
    Wildin, C. J.
    Bhowal, B.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 528 - 533
  • [4] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [5] Locking Versus Nonlocking Palmar Plate Fixation of Distal Radius Fractures
    Osti, Michael
    Mittler, Christoph
    Zinnecker, Richard
    Westreicher, Christoph
    Allhoff, Clemens
    Benedetto, Karl Peter
    [J]. ORTHOPEDICS, 2012, 35 (11) : E1613 - E1617
  • [6] Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation
    Satake, Hiroshi
    Hanaka, Naomi
    Honma, Ryusuke
    Watanabe, Tadayoshi
    Inoue, Shigeru
    Kanauchi, Yumiko
    Kato, Yoshihiro
    Nakajima, Taku
    Sato, Daisuke
    Eto, Jun
    Maruyama, Masahiro
    Naganuma, Yasushi
    Sasaki, Junya
    Toyono, Shuji
    Harada, Mikio
    Ishigaki, Daisuke
    Takahara, Masatoshi
    Takagi, Michiaki
    [J]. ORTHOPEDICS, 2016, 39 (05) : E893 - E896
  • [7] Screw length in volar locking plate fixation for distal radial fractures
    Yuen, Grace
    Yee, Dennis K. H.
    Fang, Christian
    Lau, Tak-Wing
    Leung, Frankie
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 164 - 167
  • [8] Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures
    Kaneshiro, Yasunori
    Hyun, Seungho
    Yano, Koichi
    Yokoi, Takuya
    Sakanaka, Hideki
    Hidaka, Noriaki
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (06): : 553 - 558
  • [9] Outcomes of Primary Volar Locking Plate Fixation of Open Distal Radius Fractures
    Joo, Min Su
    Kang, Hong Je
    Yu, Hyun Kyu
    Lee, Jae Sung
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (03): : 517 - 523
  • [10] Screw Prominence of Locking Plating in Distal Radius Fractures
    Sugun, Tahir Sadik
    Ozaksar, Kemal
    Gurbuz, Yusuf
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12): : 2646 - 2647