Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures

被引:1
|
作者
Kaneshiro, Yasunori [1 ]
Hyun, Seungho [1 ]
Yano, Koichi [1 ]
Yokoi, Takuya [1 ]
Sakanaka, Hideki [1 ]
Hidaka, Noriaki [2 ]
机构
[1] Seikeikai Hosp, Hand & Microsurg Ctr, Dept Orthopaed Surg, 1-1-1 Minamiyasui Cho, Sakai, Osaka 5900064, Japan
[2] Osaka City Gen Hosp, Dept Orthopaed Surg, Osaka, Japan
来源
关键词
Computed tomography; distal radius fracture; intra-articular fracture; osteosynthesis; DORSAL; COMPLICATIONS; RUPTURE; VIEW;
D O I
10.1016/j.jhsa.2023.02.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Volar locking plate fixation for distal radius fractures (DRFs) is a technically demanding procedure with a risk of distal screw penetration through the dorsal cortex or the articular surface. This study aimed to investigate the incidence and details of distal screw penetration after volar locking plate fixation for intra-articular DRFs using a CT scan and to evaluate the relationship between the incidence of screw penetration and fracture comminution severity and the clinical complications of screw penetration. Methods This was a retrospective case series of 91 adult patients (mean age, 63 years; 27 men) who underwent volar locking plate fixation for intra-articular DRFs from 2015 to 2018. The positioning of the distal screws was evaluated using a postoperative CT scan, and radiological outcomes were compared between the AO C1 and C3 groups. At the final follow-up, tendon rupture and arthritis severity were assessed as clinical complications of dorsal and intra-articular screw penetration. Results Distal screw penetration was observed in 44 wrists (48%), dorsal cortex screw penetration in 34, intra-articular screw penetration in 13, and both dorsal cortex and intraarticular screw penetration in three. The incidence of intra-articular screw penetration was significantly higher in the C3 group than in the C1 group. No tendon rupture was observed. Multivariable analysis revealed that intra-articular screw penetration was significantly related to high severity of arthritis. Conclusions Approximately half of the study patients with intra-articular DRFs had distal screw penetration. The incidence of intra-articular screw penetration was associated with the severity of fracture comminution, and the intra-articular screw penetration was associated with the incidence of early radiocarpal arthritis. Intra-articularly penetrating screws should be replaced as soon as they are discovered, regardless of the length of penetrated screw or absence of patients' subjective symptoms. (J Hand Surg Am. 2023;48(6):553-558. Copyright (C) 2023 by the American Society for Surgery of the Hand. All rights reserved.) Type of study/level of evidence Therapeutic IV.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 50 条
  • [1] Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures with Volar Lunate Facet Fragments Distal to the Watershed Line
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    [J]. JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (01) : 24 - 31
  • [2] Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture
    Diong, Teik Wei
    Haflah, Nor Hazla Mohamed
    Kassim, Abdul Yazid Mohd
    Al Habshi, Sharifah Majedah Idrus
    Shukur, Mohd Hassan
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2018, 23 (01): : 26 - 32
  • [3] Volar Plate Fixation of Intra-Articular Distal Radius Fractures: A Retrospective Study
    Fok, Margaret W. M.
    Klausmeyer, Melissa A.
    Fernandez, Diego L.
    Orbay, Jorge L.
    Bergada, Alex Lluch
    [J]. JOURNAL OF WRIST SURGERY, 2013, 2 (03) : 247 - 254
  • [4] Volar plate fixation in intra-articular distal radius fractures with a volar lunate facet fragment
    Benis, S.
    Vanhove, W.
    Hollevoet, N.
    [J]. HAND SURGERY & REHABILITATION, 2020, 39 (04): : 270 - 274
  • [5] A Randomized Comparison of Volar Plate and External Fixation for Intra-Articular Distal Radius Fractures
    Roh, Young Hak
    Lee, Beom Koo
    Baek, Jong Ryoon
    Noh, Jung Ho
    Gong, Hyun Sik
    Baek, Goo Hyun
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 34 - 41
  • [6] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [7] Intra-Articular Fractures of the Distal Radius Evaluated by Computed Tomography
    Tanabe, Katsuhisa
    Nakajima, Takaya
    Sogo, Eiji
    Denno, Kakuro
    Horiki, Mitsuru
    Nakagawa, Reiko
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (11): : 1798 - 1803
  • [8] Plate fixation with locking screw for distal fractures of the radius
    Cognet, J. -M.
    Geanah, A.
    Marsal, C.
    Kadoch, V.
    Gouzou, S.
    Simon, P.
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (07): : 663 - 672
  • [9] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    [J]. BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [10] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308