Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection

被引:22
|
作者
Sun, Yan-Mei [1 ]
Wu, Hai-Long [1 ]
Wang, Jian-Yao [1 ]
Liu, Zhi [1 ]
Zhai, Min [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Propolis; Flavonoids; HPLC-DAD; ATLD; Second-order advantage; PARALLEL FACTOR-ANALYSIS; 3RD-ORDER MULTIVARIATE CALIBRATION; HPLC-DAD; FLUORESCENCE DETECTION; BACKGROUND DRIFT; PHENOLIC-ACIDS; 2ND-ORDER; QUANTIFICATION; METHODOLOGIES; SENSITIVITY;
D O I
10.1016/j.jchromb.2014.05.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast analytical strategy of second-order calibration method based on the alternating trilinear decomposition algorithm (ATLD)-assisted high performance liquid chromatography coupled with a diode array detector (HPLC-DAD) was established for the simultaneous determination of eight flavonoids (rutin, quercetin, luteolin, kaempferol, isorhamnetin, apigenin, galangin and chrysin) in propolis capsules samples. The chromatographic separation was implemented on a Wondasil (TM) C18 column (250 mm x 4.6 mm, 5 mu m) within 13 min with a binary mobile phase composed of water with 1% formic acid and methanol at a flow rate of 1.0 mL min(-1) after flavonoids were only extracted with methanol by ultrasound extraction for 15 min. The baseline problem was overcome by considering background drift as additional compositions or factors as well as the target analytes, and ATLD was employed to handle the overlapping peaks from analytes of interest or from analytes and co-eluting matrix compounds. The linearity was good with the correlation coefficients no less than 0.9947; the limit of detections (LODs) within the range of 3.39-33.05 ng mL(-1) were low enough; the accuracy was confirmed by the recoveries ranged from 91.9% to 110.2% and the root-mean-square-error of predictions (RMSEPs) less than 1.1 mu g/mL. The results indicated that the chromatographic method with the aid of ATLD is efficient, sensitive and cost-effective and can realize the resolution and accurate quantification of flavonoids even in the presence of interferences, thus providing an alternative method for accurate quantification of analytes especially when the complete separation is not easily accomplished. The method was successfully applied to propolis capsules samples and the satisfactory results were obtained. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [21] Simultaneous Determination of Four Compounds in Sanjing Shuang-huanglian Oral Liquid by High Performance Liquid Chromatography-Diode Array Detection-Electrochemical Detection
    Liu Lin
    Suo Zhirong
    Zheng Jianbin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (03) : 247 - 250
  • [22] Determination of cyprodinil and fludioxonil in the fermentative process of must by high-performance liquid chromatography-diode array detection
    Vaquero-Fernandez, Luis
    Saenz-Hernaez, Ana
    Sanz-Asensio, Jesus
    Fernandez-Zurbano, Purificacion
    Sainz-Ramirez, Miguel
    Pons-Jubera, Begona
    Lopez-Alonso, Miguel
    Epifanio-Fernandez, Sara-Isabel
    Martinez-Soria, Maria-Teresa
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2008, 88 (11) : 1943 - 1948
  • [23] Development and validation of a High Performance Liquid Chromatography-Diode Array Detection method for the determination of aging markers in tequila
    Celia Munoz-Munoz, Ana
    Charles Grenier, Adam
    Gutierrez-Pulido, Humberto
    Cervantes-Martinez, Jesus
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 218 - 223
  • [24] Simultaneous determination of ranitidine and metronidazole in human plasma using high performance liquid chromatography with diode array detection
    do Nascimento, TG
    Oliveira, EDJ
    Macêdo, RO
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (04) : 777 - 783
  • [25] Simultaneous Determination of Eight Flavonoids in the Flowers of Matricaria chamomilla by High Performance Liquid Chromatography
    Xie, Xiao-Yu
    Chen, Fang-Fang
    Shi, Yan-Ping
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (03) : 778 - 783
  • [26] SIMULTANEOUS DETERMINATION OF EIGHT FLAVONOIDS AND POGOSTONE IN POGOSTEMON CABLIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Li, Ping
    Yin, Zhi-Qi
    Li, Song-Lin
    Huang, Xiao-Jun
    Ye, Wen-Cai
    Zhang, Qing-Wen
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (12) : 1771 - 1784
  • [27] Determination of squalene using high-performance liquid chromatography with diode array detection
    Lu, HT
    Jiang, Y
    Chen, F
    CHROMATOGRAPHIA, 2004, 59 (5-6) : 367 - 371
  • [28] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [29] Simultaneous quantification of Gemcitabine and Irinotecan hydrochloride in rat plasma by using high performance liquid chromatography-diode array detector
    Malatesta, L.
    Cosco, D.
    Paolino, D.
    Cilurzo, F.
    Costa, N.
    Di Tullio, A.
    Fresta, M.
    Celia, C.
    Di Marzio, L.
    Locatelli, M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 192 - 199
  • [30] Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography-diode array detection
    Tomic, Tatjana
    Babic, Sandra
    Nasipak, Nada Uzorinac
    Ruszkowski, Maja Fabulic
    Skrobonja, Livijana
    Kastelan-Macan, Marija
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3819 - 3824