Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography-diode array detection

被引:7
|
作者
Tomic, Tatjana [2 ]
Babic, Sandra [1 ]
Nasipak, Nada Uzorinac [2 ]
Ruszkowski, Maja Fabulic [2 ]
Skrobonja, Livijana [3 ]
Kastelan-Macan, Marija [1 ]
机构
[1] Univ Zagreb, Dept Analyt Chem, Fac Chem Engn & Technol, Zagreb 41000, Croatia
[2] INA Ind Nafte Dd, Corp Proc Funct, Res & Dev Sector, Cent Testing Lab, Zagreb, Croatia
[3] INA Ind Nafte Dd, Rijeka Oil Refinery, Urinj Bb, Rijeka, Croatia
关键词
Alkene; FCC liquid products; HPLC-DAD; Validation; GASOLINE; COLUMN;
D O I
10.1016/j.chroma.2009.02.062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alkene content determinations in fluid catalytic cracking (FCC) liquid products were performed by means of normal-phase high-performance liquid chromatography (NP-HPLC) with diode array detection (UV/DAD). Separation of alkenes from aromatic hydrocarbons was performed on amino-modified silica gel column with n-heptane as mobile phase. The column has a little affinity to alkenes and saturated hydrocarbons and a pronounced affinity to aromatic compounds. The problem of alkenes and saturates co-elution on this column type was overcome with the detection system, UV/DAD, sensitive and selective to alkenes, while saturates are inactive in UV field. Total alkene content was determined as a sum of mono-and dialkene groups quantified by external standard method. Validation and verification of the developed method proved their applicability. The following criteria were used to validate the HPLC-DAD method: selectivity, linearity, precision, limits of detection and quantification. Alkene contents were quantified with the external standard method of wide calibration range, so both low and high alkene contents can be determined by the single calibration. Correlation coefficients were higher than 0.99. Precision was evaluated as repeatability and intermediary precision with relative standard deviations less than 5%. Some structural investigation of alkene groups was performed to confirm the assumption. Proposed method was compared with certified NMR method. Six commercial motor gasoline samples were analyzed by these two methods. Obtained results indicate good agreement between alkene content determined by both methods. The developed method was applied to the determination of alkene content in liquid FCC products in the boiling range from 70 degrees C to 190 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3819 / 3824
页数:6
相关论文
共 50 条
  • [1] Determination of Parabens in Cosmetics by Liquid-Phase Microextractions and High-Performance Liquid Chromatography-Diode Array Detection
    Jain, Archana
    Soni, Soumitra
    Verma, Krishna K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (01) : 82 - 91
  • [2] Determination of cyprodinil and fludioxonil in the fermentative process of must by high-performance liquid chromatography-diode array detection
    Vaquero-Fernandez, Luis
    Saenz-Hernaez, Ana
    Sanz-Asensio, Jesus
    Fernandez-Zurbano, Purificacion
    Sainz-Ramirez, Miguel
    Pons-Jubera, Begona
    Lopez-Alonso, Miguel
    Epifanio-Fernandez, Sara-Isabel
    Martinez-Soria, Maria-Teresa
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2008, 88 (11) : 1943 - 1948
  • [3] Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry
    Hostetler, KA
    Thurman, EM
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 248 (2-3) : 147 - 155
  • [4] DETERMINATION OF PLUMBAGIN BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GUPTA, MM
    VERMA, RK
    UNIYAL, GC
    JAIN, SP
    JOURNAL OF CHROMATOGRAPHY, 1993, 637 (02): : 209 - 212
  • [5] Peak purity determination with principal component analysis of high-performance liquid chromatography-diode array detection data
    Wiberg, Kent
    Andersson, Mattias
    Hagman, Anders
    Jacobsson, Sven P.
    Journal of Chromatography A, 2004, 1029 (1-2) : 13 - 20
  • [6] Determination of triazines and N-methylcarbamate pesticides in water by high-performance liquid chromatography-diode array detection
    Topuz, S
    Alpertunga, B
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (09) : 787 - 795
  • [7] Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection
    Suh, Joon Hyuk
    Yang, Dong-Hyug
    Lee, Byung Kyu
    Eom, Han Young
    Kim, Unyong
    Kim, Junghyun
    Lee, Hyeyeon
    Han, Sang Beom
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (08) : 2648 - 2656
  • [8] Determination of imipenem and rifampicin in mouse plasma by high performance liquid chromatography-diode array detection
    Fernandez-Torres, R.
    Bello-Lopez, M. A.
    Callejon-Mochon, M.
    Jimenez-Sanchez, J. C.
    ANALYTICA CHIMICA ACTA, 2008, 608 (02) : 204 - 210
  • [9] Simultaneous determination of phosphorus and silicon by normal-phase high-performance liquid chromatography
    Basova, EM
    Kondik, EY
    Dorokhova, EN
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (02) : 133 - 139
  • [10] USE OF ELECTROCHEMICAL DETECTION IN NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GUNASINGHAM, H
    FLEET, B
    JOURNAL OF CHROMATOGRAPHY, 1983, 261 (01): : 43 - 53