Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography-diode array detection

被引:7
|
作者
Tomic, Tatjana [2 ]
Babic, Sandra [1 ]
Nasipak, Nada Uzorinac [2 ]
Ruszkowski, Maja Fabulic [2 ]
Skrobonja, Livijana [3 ]
Kastelan-Macan, Marija [1 ]
机构
[1] Univ Zagreb, Dept Analyt Chem, Fac Chem Engn & Technol, Zagreb 41000, Croatia
[2] INA Ind Nafte Dd, Corp Proc Funct, Res & Dev Sector, Cent Testing Lab, Zagreb, Croatia
[3] INA Ind Nafte Dd, Rijeka Oil Refinery, Urinj Bb, Rijeka, Croatia
关键词
Alkene; FCC liquid products; HPLC-DAD; Validation; GASOLINE; COLUMN;
D O I
10.1016/j.chroma.2009.02.062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alkene content determinations in fluid catalytic cracking (FCC) liquid products were performed by means of normal-phase high-performance liquid chromatography (NP-HPLC) with diode array detection (UV/DAD). Separation of alkenes from aromatic hydrocarbons was performed on amino-modified silica gel column with n-heptane as mobile phase. The column has a little affinity to alkenes and saturated hydrocarbons and a pronounced affinity to aromatic compounds. The problem of alkenes and saturates co-elution on this column type was overcome with the detection system, UV/DAD, sensitive and selective to alkenes, while saturates are inactive in UV field. Total alkene content was determined as a sum of mono-and dialkene groups quantified by external standard method. Validation and verification of the developed method proved their applicability. The following criteria were used to validate the HPLC-DAD method: selectivity, linearity, precision, limits of detection and quantification. Alkene contents were quantified with the external standard method of wide calibration range, so both low and high alkene contents can be determined by the single calibration. Correlation coefficients were higher than 0.99. Precision was evaluated as repeatability and intermediary precision with relative standard deviations less than 5%. Some structural investigation of alkene groups was performed to confirm the assumption. Proposed method was compared with certified NMR method. Six commercial motor gasoline samples were analyzed by these two methods. Obtained results indicate good agreement between alkene content determined by both methods. The developed method was applied to the determination of alkene content in liquid FCC products in the boiling range from 70 degrees C to 190 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3819 / 3824
页数:6
相关论文
共 50 条
  • [21] Determination of thiram in wheat flour and flour improvers by high performance liquid chromatography-diode array detection
    Wang Xuxin
    Zhou Shukun
    Li Xiaomin
    Zhang Qinghe
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (06) : 652 - 658
  • [22] NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF TRIACYLGLYCEROLS
    RHODES, SH
    NETTING, AG
    JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01): : 135 - 143
  • [23] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [24] Determination of Chlorophylls in Taraxacum formosanum by High-Performance Liquid Chromatography-Diode Array Detection-Mass Spectrometry and Preparation by Column Chromatography
    Loh, Chin Hoe
    Inbaraj, Baskaran Stephen
    Liu, Man Hai
    Chen, Bing Huei
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (24) : 6108 - 6115
  • [25] NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CAROTENES
    RHODES, SH
    NETTING, AG
    MILBORROW, BV
    JOURNAL OF CHROMATOGRAPHY, 1988, 442 : 412 - 419
  • [26] Evaporative light scattering detector in normal-phase high-performance liquid chromatography determination of FAME oxidation products
    Morales, Arturo
    Marmesat, Susana
    Carmen Dobarganes, M.
    Marquez-Ruiz, Gloria
    Velasco, Joaquin
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1254 : 62 - 70
  • [27] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF COAL-LIQUEFACTION PROCESS STREAMS USING NORMAL-PHASE SEPARATION WITH DIODE-ARRAY DETECTION
    MCKINNEY, DE
    CLIFFORD, DJ
    HOU, L
    BOGDAN, MR
    HATCHER, PG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 81 - FUEL
  • [28] DETERMINATION OF APROPHEN IN BIOLOGICAL SAMPLES BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ECK, WS
    GRAY, RR
    GEGOUX, TA
    SCHOO, GM
    STRICKLER, MP
    JOURNAL OF CHROMATOGRAPHY, 1981, 219 (01): : 171 - 174
  • [29] DETERMINATION OF CAROTENOIDS, CHLOROPHYLLS AND PHEOPHYTINS BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FERNANDEZLOPEZ, JA
    ALMELA, L
    LOPEZROCA, JM
    PHOTOSYNTHETICA, 1991, 25 (01) : 81 - 86
  • [30] Salt-assisted liquid-liquid microextraction for the determination of iodine in table salt by high-performance liquid chromatography-diode array detection
    Gupta, Manju
    Pillai, Aradhana K. K. V.
    Singh, Amrita
    Jain, Archana
    Verma, Krishna K.
    FOOD CHEMISTRY, 2011, 124 (04) : 1741 - 1746