Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography-diode array detection

被引:7
|
作者
Tomic, Tatjana [2 ]
Babic, Sandra [1 ]
Nasipak, Nada Uzorinac [2 ]
Ruszkowski, Maja Fabulic [2 ]
Skrobonja, Livijana [3 ]
Kastelan-Macan, Marija [1 ]
机构
[1] Univ Zagreb, Dept Analyt Chem, Fac Chem Engn & Technol, Zagreb 41000, Croatia
[2] INA Ind Nafte Dd, Corp Proc Funct, Res & Dev Sector, Cent Testing Lab, Zagreb, Croatia
[3] INA Ind Nafte Dd, Rijeka Oil Refinery, Urinj Bb, Rijeka, Croatia
关键词
Alkene; FCC liquid products; HPLC-DAD; Validation; GASOLINE; COLUMN;
D O I
10.1016/j.chroma.2009.02.062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alkene content determinations in fluid catalytic cracking (FCC) liquid products were performed by means of normal-phase high-performance liquid chromatography (NP-HPLC) with diode array detection (UV/DAD). Separation of alkenes from aromatic hydrocarbons was performed on amino-modified silica gel column with n-heptane as mobile phase. The column has a little affinity to alkenes and saturated hydrocarbons and a pronounced affinity to aromatic compounds. The problem of alkenes and saturates co-elution on this column type was overcome with the detection system, UV/DAD, sensitive and selective to alkenes, while saturates are inactive in UV field. Total alkene content was determined as a sum of mono-and dialkene groups quantified by external standard method. Validation and verification of the developed method proved their applicability. The following criteria were used to validate the HPLC-DAD method: selectivity, linearity, precision, limits of detection and quantification. Alkene contents were quantified with the external standard method of wide calibration range, so both low and high alkene contents can be determined by the single calibration. Correlation coefficients were higher than 0.99. Precision was evaluated as repeatability and intermediary precision with relative standard deviations less than 5%. Some structural investigation of alkene groups was performed to confirm the assumption. Proposed method was compared with certified NMR method. Six commercial motor gasoline samples were analyzed by these two methods. Obtained results indicate good agreement between alkene content determined by both methods. The developed method was applied to the determination of alkene content in liquid FCC products in the boiling range from 70 degrees C to 190 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3819 / 3824
页数:6
相关论文
共 50 条
  • [31] Improved normal-phase high-performance liquid chromatography procedure for the determination of carotenoids in cereals
    Panfili, G
    Fratianni, A
    Irano, M
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (21) : 6373 - 6377
  • [32] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants
    Farajzadeh, Mir Ali
    Bahram, Morteza
    Jonsson, Jan Ake
    ANALYTICA CHIMICA ACTA, 2007, 591 (01) : 69 - 79
  • [33] Determination of malathion and its residues by normal-phase high-performance liquid chromatography method
    Velkoska-Markovska, Lenche
    Petanovska-Ilievska, Biljana
    ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 315 - 322
  • [34] Simultaneous determination of four triterpenoids of Ganoderma lucidum by reverse-phase high-performance liquid chromatography-diode array detector
    Li, Ying-Bo
    Liang, Cui-Xia
    Liu, Ru-Ming
    Zhong, Jian-Jiang
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S43 - S43
  • [35] High Performance Liquid Chromatography-Diode Array Detector Method for the Determination of Tartrazine and Indigotine
    Yalcin, Guler
    Seyhan, Suleyman
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 8867 - 8874
  • [36] Simultaneous determination of monomeric and oligomeric alkannins and shikonins by high-performance liquid chromatography-diode array detection-mass spectrometry
    Assimopoulou, A. N.
    Ganzera, M.
    Stuppner, H.
    Papageorgiou, V. P.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (02) : 173 - 190
  • [37] THE ELECTROLYTIC EFFICIENCY OF AMPEROMETRIC DETECTION IN NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GUNASINGHAM, H
    TAY, BT
    ANG, KP
    ANALYTICA CHIMICA ACTA, 1985, 176 (OCT) : 143 - 150
  • [38] Simultaneous analysis of Vitamins A and E in infant milk-based formulae by normal-phase high-performance liquid chromatography-diode array detection using a short narrow-bore column
    Chavez-Servin, Jorge L.
    Castellote, Ana I.
    Lopez-Sabater, M. Carmen
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) : 138 - 143
  • [39] Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink
    Diaz-Santana, Oscar
    Vega-Moreno, Daura
    Conde-Hardisson, Francisco
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 187 - 195
  • [40] Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector
    Jeong, Hyun Cheol
    Hong, Hee-Do
    Kim, Young-Chan
    Rhee, Young Kyoung
    Choi, Sang Yoon
    Kim, Kyung-Tack
    Kim, Sung Soo
    Lee, Young-Chul
    Cho, Chang-Won
    PHARMACOGNOSY MAGAZINE, 2015, 11 (43) : 657 - 664