Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection

被引:22
|
作者
Sun, Yan-Mei [1 ]
Wu, Hai-Long [1 ]
Wang, Jian-Yao [1 ]
Liu, Zhi [1 ]
Zhai, Min [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Propolis; Flavonoids; HPLC-DAD; ATLD; Second-order advantage; PARALLEL FACTOR-ANALYSIS; 3RD-ORDER MULTIVARIATE CALIBRATION; HPLC-DAD; FLUORESCENCE DETECTION; BACKGROUND DRIFT; PHENOLIC-ACIDS; 2ND-ORDER; QUANTIFICATION; METHODOLOGIES; SENSITIVITY;
D O I
10.1016/j.jchromb.2014.05.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast analytical strategy of second-order calibration method based on the alternating trilinear decomposition algorithm (ATLD)-assisted high performance liquid chromatography coupled with a diode array detector (HPLC-DAD) was established for the simultaneous determination of eight flavonoids (rutin, quercetin, luteolin, kaempferol, isorhamnetin, apigenin, galangin and chrysin) in propolis capsules samples. The chromatographic separation was implemented on a Wondasil (TM) C18 column (250 mm x 4.6 mm, 5 mu m) within 13 min with a binary mobile phase composed of water with 1% formic acid and methanol at a flow rate of 1.0 mL min(-1) after flavonoids were only extracted with methanol by ultrasound extraction for 15 min. The baseline problem was overcome by considering background drift as additional compositions or factors as well as the target analytes, and ATLD was employed to handle the overlapping peaks from analytes of interest or from analytes and co-eluting matrix compounds. The linearity was good with the correlation coefficients no less than 0.9947; the limit of detections (LODs) within the range of 3.39-33.05 ng mL(-1) were low enough; the accuracy was confirmed by the recoveries ranged from 91.9% to 110.2% and the root-mean-square-error of predictions (RMSEPs) less than 1.1 mu g/mL. The results indicated that the chromatographic method with the aid of ATLD is efficient, sensitive and cost-effective and can realize the resolution and accurate quantification of flavonoids even in the presence of interferences, thus providing an alternative method for accurate quantification of analytes especially when the complete separation is not easily accomplished. The method was successfully applied to propolis capsules samples and the satisfactory results were obtained. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [41] Application and validation of chemometrics-assisted spectrophotometry and liquid chromatography for the simultaneous determination of six-component pharmaceuticals
    El-Gindy, Alaa
    Emara, Samy
    Mostafa, Ahmed
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) : 421 - 430
  • [42] Simultaneous determination of four triterpenoids of Ganoderma lucidum by reverse-phase high-performance liquid chromatography-diode array detector
    Li, Ying-Bo
    Liang, Cui-Xia
    Liu, Ru-Ming
    Zhong, Jian-Jiang
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S43 - S43
  • [43] Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography-Diode array detection data and second order algorithms
    Culzoni, Maria J.
    Schenone, Agustina V.
    Llamas, Natalia E.
    Garrido, Mariano
    Di Nezio, Maria S.
    Fernandez Band, Beatriz S.
    Goicoechea, Hector C.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (42) : 7063 - 7070
  • [44] One single standard substance for the determination of multiple anthraquinone derivatives in rhubarb using high-performance liquid chromatography-diode array detection
    Gao, Xiao-Yan
    Jiang, Yong
    Lu, Jian-qiu
    Tu, Peng-Fei
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2118 - 2123
  • [45] Determination of two antifouling booster biocides and their degradation products in marine sediments by high performance liquid chromatography-diode array detection
    Gatidou, G
    Kotrikla, A
    Thomaidis, NS
    Lekkas, TD
    ANALYTICA CHIMICA ACTA, 2004, 505 (01) : 153 - 159
  • [46] Analysis of Products of Degradation and Side Reactions of Proanthocyanidin by High Performance Liquid Chromatography-Diode Array Detection
    Zhang Liang-Liang
    Lin Yi-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (09) : 1281 - 1284
  • [47] Identification of impurities in lovastatin by high performance liquid chromatography-diode array detection-mass spectrometry
    Wu, YJ
    Zhu, W
    Shao, Q
    Cheng, YY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (01) : 115 - 118
  • [48] Determination of 10 Caffeoylquinic Acids and 22 Flavonoids in Chrysanthemum Samples by Ultra-high Performance Liquid Chromatography-Diode Array Detection-Tandem Mass Spectrometry
    Zhang Wei-Bing
    Wang Zhi-Cong
    Zhang Ling-Yi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (12) : 1851 - 1861
  • [49] Determination of Tyrian purple by high performance liquid chromatography with diode array detection
    Vasileiadou, Athina
    Karapanagiotis, Ioannis
    Zotou, Anastasia
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1448 : 67 - 72
  • [50] Analysis of active compounds and geographical origin discrimination of Atractylodes macrocephala Koidz. by using high performance liquid chromatography-diode array detection fingerprints combined with chemometrics
    Tong, Gao-Yan
    Wu, Hai-Long
    Wang, Tong
    Chang, Yue-Yue
    Chen, Yao
    Yang, Jian
    Fu, Hai-Yan
    Yang, Xiao-Long
    Li, Xu-Fu
    Yu, Ru-Qin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1674