Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection

被引:22
|
作者
Sun, Yan-Mei [1 ]
Wu, Hai-Long [1 ]
Wang, Jian-Yao [1 ]
Liu, Zhi [1 ]
Zhai, Min [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Propolis; Flavonoids; HPLC-DAD; ATLD; Second-order advantage; PARALLEL FACTOR-ANALYSIS; 3RD-ORDER MULTIVARIATE CALIBRATION; HPLC-DAD; FLUORESCENCE DETECTION; BACKGROUND DRIFT; PHENOLIC-ACIDS; 2ND-ORDER; QUANTIFICATION; METHODOLOGIES; SENSITIVITY;
D O I
10.1016/j.jchromb.2014.05.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast analytical strategy of second-order calibration method based on the alternating trilinear decomposition algorithm (ATLD)-assisted high performance liquid chromatography coupled with a diode array detector (HPLC-DAD) was established for the simultaneous determination of eight flavonoids (rutin, quercetin, luteolin, kaempferol, isorhamnetin, apigenin, galangin and chrysin) in propolis capsules samples. The chromatographic separation was implemented on a Wondasil (TM) C18 column (250 mm x 4.6 mm, 5 mu m) within 13 min with a binary mobile phase composed of water with 1% formic acid and methanol at a flow rate of 1.0 mL min(-1) after flavonoids were only extracted with methanol by ultrasound extraction for 15 min. The baseline problem was overcome by considering background drift as additional compositions or factors as well as the target analytes, and ATLD was employed to handle the overlapping peaks from analytes of interest or from analytes and co-eluting matrix compounds. The linearity was good with the correlation coefficients no less than 0.9947; the limit of detections (LODs) within the range of 3.39-33.05 ng mL(-1) were low enough; the accuracy was confirmed by the recoveries ranged from 91.9% to 110.2% and the root-mean-square-error of predictions (RMSEPs) less than 1.1 mu g/mL. The results indicated that the chromatographic method with the aid of ATLD is efficient, sensitive and cost-effective and can realize the resolution and accurate quantification of flavonoids even in the presence of interferences, thus providing an alternative method for accurate quantification of analytes especially when the complete separation is not easily accomplished. The method was successfully applied to propolis capsules samples and the satisfactory results were obtained. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [31] Peak purity determination with principal component analysis of high-performance liquid chromatography-diode array detection data
    Wiberg, Kent
    Andersson, Mattias
    Hagman, Anders
    Jacobsson, Sven P.
    Journal of Chromatography A, 2004, 1029 (1-2) : 13 - 20
  • [32] Determination of triazines and N-methylcarbamate pesticides in water by high-performance liquid chromatography-diode array detection
    Topuz, S
    Alpertunga, B
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (09) : 787 - 795
  • [33] High Performance Liquid Chromatography-Diode Array Detector Method for the Simultaneous Determination of Five Compounds in the Pulp and Seed of Sea Buckthorn
    Zhao, Lu
    Wen, E.
    Upur, Halmuart
    Tian, Shuge
    PHARMACOGNOSY MAGAZINE, 2017, 13 (49) : 136 - 140
  • [34] Simultaneous determination of four components in commercial analgesic tablets by reversed phase high performance liquid chromatography-diode array detector
    Liu, DJ
    Wang, X
    Sun, JL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1106 - 1108
  • [35] Simultaneous Determination of 18 Bioactive Compounds in Italian Bitter Liqueurs by Reversed-Phase High-Performance Liquid Chromatography-Diode Array Detection
    Mustafa, Ahmed M.
    Ricciutelli, Massimo
    Maggi, Filippo
    Sagratini, Gianni
    Vittori, Sauro
    Caprioli, Giovanni
    FOOD ANALYTICAL METHODS, 2014, 7 (03) : 697 - 705
  • [36] SIMULTANEOUS DETERMINATION OF FOUR FLAVONOID AGLYCONE ANALOGS IN THE INFLORESCENCE OF JUGLANS REGIA L. BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION
    Zhao, Lei
    Li, Jintian
    Wang, Tongwen
    Liu, Lina
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (14) : 1986 - 1998
  • [37] Simultaneous Determination of Flavonoids, Isochlorogenic Acids and Triterpenoids in Ilex hainanensis Using High Performance Liquid Chromatography Coupled with Diode Array and Evaporative Light Scattering Detection
    Peng, Bo
    Qiao, Chun-Feng
    Zhao, Jing
    Huang, Wei-Hua
    Hu, De-Jun
    Liu, Hua-Gang
    Li, Shao-Ping
    MOLECULES, 2013, 18 (03) : 2934 - 2941
  • [38] A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.
    Niu, Tian-Zeng
    Zhang, Yu-Wei
    Bao, Yong-Li
    Wu, Yin
    Yu, Chun-Lei
    Sun, Lu-Guo
    Yi, Jing-Wen
    Huang, Yan-Xin
    Li, Yu-Xin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 76 : 44 - 48
  • [39] Liquid-liquid extraction combined with high performance liquid chromatography-diode array-ultra-violet for simultaneous determination of antineoplastic drugs in plasma
    Sanson, Ananda Lima
    Renno Silva, Suellen Cristina
    Goncalves Martins, Matheus Coutinho
    Giusti-Paiva, Alexandre
    Maia, Patricia Penido
    Martins, Isarita
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 47 (02) : 363 - 371
  • [40] Determination of phenolic compounds in Prunella L. by liquid chromatography-diode array detection
    Sahin, Saliha
    Demir, Cevdet
    Malyer, Hulusi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1227 - 1230