Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep

被引:30
|
作者
Yiallourou, Stephanie R. [1 ]
Walker, Adrian M. [1 ]
Horne, Rosemary S. C. [1 ]
机构
[1] Monash Univ, Monash Inst Med Res, Ritchie Ctr Baby Hlth Res, Melbourne, Vic 3004, Australia
关键词
blood pressure; baroreflex; sleep; cardiovascular control;
D O I
10.1093/sleep/29.8.1083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Accuracy and precision of a noninvasive device for continuously measuring blood pressure (BP) (Finometer (TM), FMS, The Netherlands) during sleep was assessed in preterm infants. Design: Absolute BP beat-to-beat values, interbeat changes, measurement precision, and baroreflex sensitivity were compared with BP measurements from intraarterial catheters. Participants: Ten preterm infants (gestational age 27-36 weeks; birth weight 964-2620 gm) were studied in the neonatal intensive care unit. Measurements and Results: The 2 modes of BP measurement were compared in 2-minute epochs (n = 10-12/infant). Mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure were analyzed beat to beat, and baroreflex sensitivity was assessed using spontaneous sequence analysis. Mean differences for absolute BP (mm Hg) were as follows: mean arterial pressure, 3 (limits of agreement, -1 to 8); systolic arterial pressure, -4 (-8 to 1); and diastolic arterial pressure, 7 (4 to 10). Mean differences and limits of agreement for interbeat changes were essentially 0 for mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure. Precision ( 95% confidence intervals, mm Hg) for the Finometer (TM) were mean arterial pressure +/- 7, systolic arterial pressure 8, and diastolic arterial pressure +/- 6. Precision was greater for the arterial catheter (mean arterial pressure 3, systolic arterial pressure 4, and diastolic arterial pressure 4). Baroreflex sensitivity calculated from the Finometer (TM) BP was (mean +/- SEM, ms/mm Hg) 1.74 +/- 0.23 and, from the catheter system, BP was 1.56 +/- 0.21 (p value NS). Conclusions: The Finometer (TM) provides accurate measurements of beat-to-beat BP and baroreflex sensitivity. The ability to continuously measure BP and baroreflex sensitivity during sleep in infants may provide vital clues into pathologic conditions associated with impaired autonomic control during sleep.
引用
收藏
页码:1083 / 1088
页数:6
相关论文
共 50 条
  • [41] Noninvasive estimation of baroreflex sensitivity using pressure pulse amplification: Assessing the difference between calculations made using aortic and peripheral blood pressure
    Avolio, A.
    Qasem, A.
    Park, Y.J.
    2001, Institute of Electrical and Electronics Engineers Inc. (20):
  • [42] Which is the most important factor in the relationship between cardiovascular events and obstructive sleep apnea: Blood pressure level, blood pressure variability or baroreflex sensitivity?
    Gao, Zhenhua
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (10): : 1554 - 1555
  • [43] Changes in blood pressure during sleep as determined by the Erlanger method
    Landis, C
    AMERICAN JOURNAL OF PHYSIOLOGY, 1925, 73 (03): : 551 - 555
  • [44] EXPIRATORY VOLUME CLAMPING (EVC) - A NEW NONINVASIVE METHOD TO MEASURE PASSIVE RESPIRATORY MECHANICS IN INFANTS
    GRUNSTEIN, MM
    SPRINGER, C
    GODFREY, S
    BARYISHAY, E
    VILOZNI, D
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A8 - A8
  • [45] Blood Pressure and Heart Rate Patterns During Sleep Are Altered in Preterm-Born Infants: Implications for Sudden Infant Death Syndrome
    Witcombe, Nicole B.
    Yiallourou, Stephanie R.
    Walker, Adrian M.
    Horne, Rosemary S. C.
    PEDIATRICS, 2008, 122 (06) : E1242 - E1248
  • [46] CARDIAC BAROREFLEX SENSITIVITY ASSESSMENT USING SPONTANEOUS SEQUENCE-ANALYSIS OF CONTINUOUS NONINVASIVE BLOOD-PRESSURE RECORDINGS IN MAN
    STEPTOE, A
    VOGELE, C
    JOURNAL OF PHYSIOLOGY-LONDON, 1990, 422 : P50 - P50
  • [47] Stability of the noninvasive baroreflex sensitivity assessment using cross-spectral analysis of heart rate and arterial blood pressure variabilities
    Wichterle, D
    Melenovsky, V
    Necasova, L
    Kautzner, J
    Malik, M
    CLINICAL CARDIOLOGY, 2000, 23 (03) : 201 - 204
  • [48] Validation of a new piezoelectric device for noninvasive measurement of central aortic systolic blood pressure
    Cuffaro, Paula E.
    Morales, Margarita S.
    Barochiner, Jessica
    Rada, Marcelo A.
    Alfie, Jose
    Aparicio, Lucas S.
    Galarza, Carlos R.
    Micali, Ruben G.
    Marin, Marcos J.
    Waisman, Gabriel D.
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 49 - 51
  • [49] Evaluation of baroreflex sensitivity by the sequence method using blood pressure oscillations and R-R interval changes during deep respiration
    Oka, H
    Mochio, S
    Yoshioka, M
    Morita, M
    Inoue, K
    EUROPEAN NEUROLOGY, 2003, 50 (04) : 230 - 243
  • [50] Instantaneous Cardiac Baroreflex Sensitivity: xBRS Method Quantifies Heart Rate Blood Pressure Variability Ratio at Rest and During Slow Breathing
    Wessel, Niels
    Gapelyuk, Andrej
    Weiss, Jonas
    Schmidt, Martin
    Kraemer, Jan F.
    Berg, Karsten
    Malberg, Hagen
    Stepan, Holger
    Kurths, Juergen
    FRONTIERS IN NEUROSCIENCE, 2020, 14