Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep

被引:30
|
作者
Yiallourou, Stephanie R. [1 ]
Walker, Adrian M. [1 ]
Horne, Rosemary S. C. [1 ]
机构
[1] Monash Univ, Monash Inst Med Res, Ritchie Ctr Baby Hlth Res, Melbourne, Vic 3004, Australia
关键词
blood pressure; baroreflex; sleep; cardiovascular control;
D O I
10.1093/sleep/29.8.1083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Accuracy and precision of a noninvasive device for continuously measuring blood pressure (BP) (Finometer (TM), FMS, The Netherlands) during sleep was assessed in preterm infants. Design: Absolute BP beat-to-beat values, interbeat changes, measurement precision, and baroreflex sensitivity were compared with BP measurements from intraarterial catheters. Participants: Ten preterm infants (gestational age 27-36 weeks; birth weight 964-2620 gm) were studied in the neonatal intensive care unit. Measurements and Results: The 2 modes of BP measurement were compared in 2-minute epochs (n = 10-12/infant). Mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure were analyzed beat to beat, and baroreflex sensitivity was assessed using spontaneous sequence analysis. Mean differences for absolute BP (mm Hg) were as follows: mean arterial pressure, 3 (limits of agreement, -1 to 8); systolic arterial pressure, -4 (-8 to 1); and diastolic arterial pressure, 7 (4 to 10). Mean differences and limits of agreement for interbeat changes were essentially 0 for mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure. Precision ( 95% confidence intervals, mm Hg) for the Finometer (TM) were mean arterial pressure +/- 7, systolic arterial pressure 8, and diastolic arterial pressure +/- 6. Precision was greater for the arterial catheter (mean arterial pressure 3, systolic arterial pressure 4, and diastolic arterial pressure 4). Baroreflex sensitivity calculated from the Finometer (TM) BP was (mean +/- SEM, ms/mm Hg) 1.74 +/- 0.23 and, from the catheter system, BP was 1.56 +/- 0.21 (p value NS). Conclusions: The Finometer (TM) provides accurate measurements of beat-to-beat BP and baroreflex sensitivity. The ability to continuously measure BP and baroreflex sensitivity during sleep in infants may provide vital clues into pathologic conditions associated with impaired autonomic control during sleep.
引用
收藏
页码:1083 / 1088
页数:6
相关论文
共 50 条
  • [31] Validation of a preterm infant cardiovascular system model under baroreflex control with heart rate and blood pressure data
    Jennekens, Ward
    Dat, Marco
    Bovendeerd, Peter H. M.
    Wijn, Pieter F. F.
    Andriessen, Peter
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 896 - 899
  • [32] Persistent high blood pressure and renal dysfunction in preterm infants during childhood
    Wickland, Jessica
    Brown, L. Steven
    Blanco, Valerie
    Heyne, Roy
    Turer, Christy
    Rosenfeld, Charles R.
    PEDIATRIC RESEARCH, 2023, 93 (01) : 217 - 225
  • [33] Persistent high blood pressure and renal dysfunction in preterm infants during childhood
    Jessica Wickland
    L. Steven Brown
    Valerie Blanco
    Roy Heyne
    Christy Turer
    Charles R. Rosenfeld
    Pediatric Research, 2023, 93 : 217 - 225
  • [34] CARDIOVASCULAR EFFECTS RITODRINE TOCOLYSIS - A NEW NONINVASIVE METHOD TO MEASURE PULMONARY CAPILLARY-PRESSURE DURING PREGNANCY
    HADI, HA
    ABDULLA, AM
    FADEL, HE
    STEFADOUROS, MA
    METHENY, WP
    OBSTETRICS AND GYNECOLOGY, 1987, 70 (04): : 608 - 612
  • [35] Skin-to-Skin Contact and Diaphragm Electrical Activity in Preterm Infants During Noninvasive Pressure Control
    Kato, Yuta
    Hirata, Katsuya
    Takemoto, Ayumi
    Oumi, Chiyo
    Hisaichi, Tomomi
    Shimaji, Yuki
    Momochi, Misa
    Wada, Kazuko
    ADVANCES IN NEONATAL CARE, 2024, 24 (03) : 285 - 290
  • [36] Validation of a quantitative method to measure neural respiratory drive in children during sleep
    Chuang, Sandra Ya-chu
    Teng, Arthur
    Butler, Jane Elizabeth
    Gandevia, Simon Charles
    Selvadurai, Hiran
    Jaffe, Adam
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2017, 239 : 75 - 80
  • [37] Effects of new calcium channel blocker, azelnidipine, and amlodipine on baroreflex sensitivity and ambulatory blood pressure
    Eguchi, Kazuo
    Tomizawa, Hidenori
    Ishikawa, Joji
    Hoshide, Satoshi
    Fukuda, Toshio
    Numao, Toshio
    Shimada, Kazuyuki
    Kario, Kazuomi
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2007, 49 (06) : 394 - 400
  • [38] Hydraulic Coupling A New Method for Noninvasive Intermittent Blood Pressure Monitoring
    Saugel, Bernd
    Kouz, Karim
    Sessler, Daniel I.
    ANESTHESIOLOGY, 2020, 133 (05) : 964 - 966
  • [39] New blood pressure measure method based on characteristic point
    Yuansheng, Liu
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 327 - 330
  • [40] A NEW METHOD TO MEASURE THE SHORT TERM BLOOD PRESSURE VARIABILITY
    Strocchi, E.
    Greco, T.
    Malini, P. L.
    Rosticci, M.
    Rinaldi, E. R.
    Borghi, C.
    JOURNAL OF HYPERTENSION, 2015, 33 : E254 - E254