Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results

被引:192
|
作者
Zhu, Lei [1 ]
Bennett, N. Robert
Fahrig, Rebecca
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
cone-beam CT; primary modulation; scatter correction; X-ray scatter;
D O I
10.1109/TMI.2006.884636
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object.
引用
收藏
页码:1573 / 1587
页数:15
相关论文
共 50 条
  • [21] An X-Ray Scatter Correction Method for Dedicated Breast Computed Tomography
    Sechopoulos, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3914 - 3914
  • [22] Scatter Correction in X-Ray CT by Physics-Inspired Deep Learning
    Iskender, Berk
    Bresler, Yoram
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2022, 8 : 1074 - 1088
  • [23] Improved Primary Modulation Method for Scatter Correction in Cone-Beam CT Using Local Filtration
    Zhu, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3283 - 3284
  • [24] A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4633 - 4652
  • [25] A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    Siewerdsen, JH
    Daly, MJ
    Bakhtiar, B
    Moseley, DJ
    Richard, S
    Keller, H
    Jaffray, DA
    MEDICAL PHYSICS, 2006, 33 (01) : 187 - 197
  • [26] X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT
    Aootaphao, Sorapong
    Thongvigitmanee, Saowapak S.
    Rajruangrabin, Jartuwat
    Thanasupsombat, Chalinee
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [27] A software-based x-ray scatter correction method for breast tomosynthesis
    Feng, Steve Si Jia
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2011, 38 (12) : 6643 - 6653
  • [28] EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 485 - 492
  • [29] Library based x-ray scatter correction for dedicated cone beam breast CT
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (08) : 4529 - 4544
  • [30] Scatter analysis and correction for ultrafast X-ray tomography
    Wagner, Michael
    Barthel, Frank
    Zalucky, Johannes
    Bieberle, Martina
    Hampel, Uwe
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2015, 373 (2043):