Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results

被引:192
|
作者
Zhu, Lei [1 ]
Bennett, N. Robert
Fahrig, Rebecca
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
cone-beam CT; primary modulation; scatter correction; X-ray scatter;
D O I
10.1109/TMI.2006.884636
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object.
引用
收藏
页码:1573 / 1587
页数:15
相关论文
共 50 条
  • [41] An X-ray spectrum estimation method from transmission measurement combined with scatter correction
    Kim, Guna
    Cho, Hyosung
    Lim, Ilhan
    Song, Kanghyon
    Kim, Jong-Guk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 178 - 185
  • [42] Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT
    Rit, S.
    Romero, E.
    Oliva, M. Vila
    Brousmiche, S.
    Sarrut, D.
    Letang, J. M.
    Freud, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S115 - S115
  • [43] THEORY OF X-RAY SCATTER ON A CRYSTAL OF AN AGING ALLOY
    AGISHEV, VM
    RUSSIAN METALLURGY, 1975, (03): : 133 - 137
  • [44] Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation
    Zaidi, Habib
    Ay, Mohammad Reza
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2161 - 2165
  • [45] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [46] An Analytical Approach to Correction for X-Ray Scatter in Heterogeneous Medium
    Yao, W.
    Leszczynski, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2646 - +
  • [47] A straightforward and analytical method for precise X-ray CT magnification correction
    Talebinezhad, Hossein
    Fischer, Ralf
    Shmatok, Andrii
    Prorok, Barton C.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2023, 82 : 338 - 349
  • [48] The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review
    Sayed, Mohammad
    Knapp, Karen M.
    Fulford, Jon
    Heales, Christine
    Alqahtani, Saeed J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [49] X-Ray Compton Scatter Imaging on Volumetric CT Systems
    Niu, T.
    Zhu, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [50] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)