Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results

被引:192
|
作者
Zhu, Lei [1 ]
Bennett, N. Robert
Fahrig, Rebecca
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
cone-beam CT; primary modulation; scatter correction; X-ray scatter;
D O I
10.1109/TMI.2006.884636
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object.
引用
收藏
页码:1573 / 1587
页数:15
相关论文
共 50 条
  • [31] X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2017, 44 (06) : 2312 - 2320
  • [32] Quasi-Monte Carlo method for calculating X-ray scatter in CT
    Lin, Guiyuan
    Deng, Shiwo
    Wang, Xiaoqun
    OPTICS EXPRESS, 2021, 29 (09) : 13746 - 13763
  • [33] Densely sampled spectral modulation for x-ray CT using a stationary modulator with flying focal spot: a conceptual and feasibility study of scatter and spectral correction
    Gao, Hewei
    Zhang, Tao
    Bennett, N. Robert
    Wang, Adam S.
    MEDICAL PHYSICS, 2021, 48 (04) : 1557 - 1570
  • [34] Compton Scatter in X-Ray Fluorescence CT Imaging
    Bazalova, M.
    Kuang, Y.
    Pratx, G.
    Xing, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3986 - 3986
  • [35] CONCERNING X-RAY SCATTER REDUCTION FOR CT SCANNERS
    CACAK, RK
    MEDICAL PHYSICS, 1981, 8 (02) : 249 - 249
  • [36] A METHOD FOR ESTIMATING X-RAY SCATTER SPECTRA
    MOORE, WE
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 419 : 77 - 79
  • [37] A METHOD FOR ESTIMATING X-RAY SCATTER SPECTRA
    MOORE, WE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (06) : 1357 - 1357
  • [38] A New X-Ray Scatter Estimation and Correction Method for Kilo-Voltage Cone Beam CT Assisted by Multislice CT Scans
    Rong, Y.
    Tolakanahalli, R.
    Tome, W.
    Paliwal, B.
    MEDICAL PHYSICS, 2008, 35 (06) : 2647 - +
  • [39] X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library
    Feng, Steve Si Jia
    D'Orsi, Carl J.
    Newell, Mary S.
    Seidel, Rebecca L.
    Patel, Bhavika
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2014, 41 (03)
  • [40] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):