EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT

被引:0
|
作者
Schoerner, K. [1 ]
Goldammer, M. [1 ]
Stephan, J. [1 ]
机构
[1] Siemens AG, Corp Technol, D-81739 Munich, Germany
关键词
X-ray Cone-Beam Computed Tomography; Scatter; Artifact Removal; Beam-Stop Array;
D O I
10.1063/1.3591891
中图分类号
O59 [应用物理学];
学科分类号
摘要
Scattered radiation presents a major source of image degradation in industrial cone-beam computed tomography systems. Scatter artifacts introduce streaks, cupping and a loss of contrast in the reconstructed CT-volumes. In order to overcome scatter artifacts, we present two complementary experimental correction methods: the beam-stop array (BSA) and an inverse technique we call beam-hole array (BHA). Both correction methods are examined in comparative measurements where it is shown that the aperture-based BHA technique has practical and scatter-reducing advantages over the BSA. The proposed BHA correction method is successfully applied to a large-scale industrial specimen whereby scatter artifacts are reduced and contrast is enhanced significantly.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 50 条
  • [1] A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4633 - 4652
  • [2] A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT
    Peterzol, A.
    Letang, J. M.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18): : 4042 - 4054
  • [3] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):
  • [4] X-ray scatter correction for cone-beam CT using moving blocker array
    Zhu, L
    Strobel, N
    Fahrig, R
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 251 - 258
  • [5] Overview of X-ray Scatter in Cone-beam Computed Tomography and Its Correction Methods
    Niu, Tianye
    Zhu, Lei
    CURRENT MEDICAL IMAGING REVIEWS, 2010, 6 (02) : 82 - 89
  • [6] Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT
    Rit, S.
    Romero, E.
    Oliva, M. Vila
    Brousmiche, S.
    Sarrut, D.
    Letang, J. M.
    Freud, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S115 - S115
  • [7] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [8] A direct, empirical method for x-ray scatter correction in digital radiography and cone-beam CT
    Siewerdsen, J
    Bakhtiar, B
    Moseley, D
    Richard, S
    Keller, H
    Daly, M
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2093
  • [9] Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (03): : 292 - 299
  • [10] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202