EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT

被引:0
|
作者
Schoerner, K. [1 ]
Goldammer, M. [1 ]
Stephan, J. [1 ]
机构
[1] Siemens AG, Corp Technol, D-81739 Munich, Germany
关键词
X-ray Cone-Beam Computed Tomography; Scatter; Artifact Removal; Beam-Stop Array;
D O I
10.1063/1.3591891
中图分类号
O59 [应用物理学];
学科分类号
摘要
Scattered radiation presents a major source of image degradation in industrial cone-beam computed tomography systems. Scatter artifacts introduce streaks, cupping and a loss of contrast in the reconstructed CT-volumes. In order to overcome scatter artifacts, we present two complementary experimental correction methods: the beam-stop array (BSA) and an inverse technique we call beam-hole array (BHA). Both correction methods are examined in comparative measurements where it is shown that the aperture-based BHA technique has practical and scatter-reducing advantages over the BSA. The proposed BHA correction method is successfully applied to a large-scale industrial specimen whereby scatter artifacts are reduced and contrast is enhanced significantly.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 50 条
  • [41] X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2017, 44 (06) : 2312 - 2320
  • [42] MC SIMULATION FOR ESTIMATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kV X-RAY TUBE
    Miceli, A.
    Thierry, R.
    Flisch, A.
    Sennhauser, U.
    Casali, F.
    EUROPEAN NDT DAYS IN PRAGUE 2007: NDT IN PROGRESS, PROCEEDINGS, 2007, : 111 - 120
  • [43] Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bose, Supratik
    Hristov, Dimitre H.
    Faddegon, Bruce A.
    Paidi, Ajay
    Bani-Hashemi, Ali R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1791 - 1810
  • [44] Evaluation of scatter mitigation strategies for X-ray cone-beam CT: Impact of scatter subtraction and anti-scatter grids on Contrast-toNoise ratio
    Lazos, Dimitrios
    Lasio, Giovanni
    Evans, Joshua
    Williamson, Jeffrey F.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [45] Application of cone-beam X-ray CT in dento-maxillofacial region
    Maki, K
    Usui, T
    Kubota, M
    Nakano, H
    Shibasaki, Y
    Araki, K
    Okano, T
    Ueno, K
    Yamamoto, K
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1003 - 1008
  • [46] Investigation of a Diamond X-Ray Target for Use with Megavoltage Cone-Beam CT
    Sawkey, D.
    Lu, M.
    Wu, V.
    Faddegon, B.
    Morin, O.
    Cheung, J.
    Aubin, M.
    Gangadharan, B.
    Bani-Hashemi, A.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [47] Micro cone-beam CT scanner based on X-ray polycapillary optics
    Zhou La-Zhen
    Xia Wen-Jing
    Xu Qian-Qian
    Chen Zan
    Li Fang-Zuo
    Liu Zhi-Guo
    Sun Tian-Xi
    ACTA PHYSICA SINICA, 2022, 71 (09)
  • [48] Geometry Calibration of a Modular Stereo Cone-Beam X-ray CT System
    Nguyen Van
    Sanctorum, Joaquim G.
    Van Wassenbergh, Sam
    Dirckx, Joris J. J.
    Sijbers, Jan
    De Beenhouwer, Jan
    JOURNAL OF IMAGING, 2021, 7 (03)
  • [50] Fast scatter estimation for cone-beam X-ray CT by combined Monte Carlo tracking and Richardson-Lucy fitting
    Zbijewski, W
    Beekman, FJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2774 - 2777