EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT

被引:0
|
作者
Schoerner, K. [1 ]
Goldammer, M. [1 ]
Stephan, J. [1 ]
机构
[1] Siemens AG, Corp Technol, D-81739 Munich, Germany
关键词
X-ray Cone-Beam Computed Tomography; Scatter; Artifact Removal; Beam-Stop Array;
D O I
10.1063/1.3591891
中图分类号
O59 [应用物理学];
学科分类号
摘要
Scattered radiation presents a major source of image degradation in industrial cone-beam computed tomography systems. Scatter artifacts introduce streaks, cupping and a loss of contrast in the reconstructed CT-volumes. In order to overcome scatter artifacts, we present two complementary experimental correction methods: the beam-stop array (BSA) and an inverse technique we call beam-hole array (BHA). Both correction methods are examined in comparative measurements where it is shown that the aperture-based BHA technique has practical and scatter-reducing advantages over the BSA. The proposed BHA correction method is successfully applied to a large-scale industrial specimen whereby scatter artifacts are reduced and contrast is enhanced significantly.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 50 条
  • [31] An X-Ray Fluence Modulation Apparatus for Cone-Beam CT
    Ghazi, P.
    Youssefian, S.
    Ghazi, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Optimization of the Design of a Moving Blocker for Cone-Beam CT Scatter Correction: Experimental Evaluation
    Chen, X.
    Ouyang, L.
    Yan, H.
    Jia, X.
    Zhang, Y.
    Wang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3799 - 3799
  • [33] X-ray scatter suppression algorithm for cone beam volume CT
    Ning, RL
    Tang, XY
    Conover, DL
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 774 - 781
  • [34] Development and application of high-performance cone-beam industrial X-ray CT system
    Yang Q.
    Tan B.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2023, 31 (06): : 804 - 812
  • [35] A Parameter Division Based Method for the Geometrical Calibration of X-Ray Industrial Cone-Beam CT
    Xiao, Kai
    Han, Yu
    Xi, Xiaoqi
    Yan, Bin
    Bu, Haibing
    Li, Lei
    IEEE ACCESS, 2018, 6 : 48970 - 48977
  • [36] Filtered back projection method for cone-beam X-ray CT
    Matsuo, Hiroshi, 1600, (20):
  • [37] FPGA-acceleration of cone-beam reconstruction for the X-ray CT
    Stsepankou, D
    Kornmesser, K
    Hesser, J
    Männer, R
    2004 IEEE INTERNATIONAL CONFERENCE ON FIELD-PROGRAMMABLE TECHNOLOGY, PROCEEDINGS, 2004, : 327 - 330
  • [38] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [39] Scatter measurements and simulations in x-ray cone beam CT breast imaging
    Chen, Y.
    Liu, B.
    O'Connor, M.
    Didier, C.
    Glick, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2606 - 2606
  • [40] Coherent Cone-Beam X-ray Microscopy
    Harder, R.
    Xiao, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 429 - 432