BLOOD GLUCOSE MEASUREMENT IN PATIENTS WITH SUSPECTED DIABETIC KETOACIDOSIS: A COMPARISON OF ABBOTT MEDISENSE PCX POINT-OF-CARE METER VALUES TO REFERENCE LABORATORY VALUES

被引:6
|
作者
Blank, Fidela S. J. [1 ]
Miller, Moses [2 ]
Nichols, James
Smithline, Howard [2 ]
Crabb, Gillian [2 ]
Pekow, Penelope [3 ,4 ]
机构
[1] Tufts Univ, Sch Med, Boston, MA 02111 USA
[2] Baystate Med Ctr, Dept Emergency Med, Springfield, MA USA
[3] Baystate Med Ctr, Div Healthcare Qual, Springfield, MA USA
[4] Univ Massachusetts, Sch Publ Hlth & Hlth Sci, Amherst, MA 01003 USA
关键词
Diabetic; Ketoacidosis; Blood glucose measurement; Emergency department;
D O I
10.1016/j.jen.2008.01.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). Methods: A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100, 000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Results: Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. Discussion: The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 50 条
  • [31] Comparison of point-of-care and laboratory D-dimer immunoassays in emergency department patients with suspected pulmonary embolus
    Giraldez, E. M.
    Morrissey, J.
    Kosowsky, J. M.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : S90 - S90
  • [32] Comparison of two point-of-care measurements of hemoglobin against standard laboratory values during pediatric liver transplantation: A retrospective review
    Morris, Bethany L.
    Hajduk, John
    Cheon, Eric C.
    Ballard, Heather A.
    Burjek, Nicholas E.
    [J]. PEDIATRIC ANESTHESIA, 2022, 32 (10) : 1121 - 1128
  • [33] Agreement between point-of-care glucometry, blood gas and laboratory-based measurement of glucose in an equine neonatal intensive care unit
    Russell, C.
    Palmer, J. E.
    Boston, R. C.
    Wilkins, P. A.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2007, 17 (03) : 236 - 242
  • [34] Evaluation of agreement between a noninvasive method for real-time measurement of critical blood values with a standard point-of-care device
    Ettrich, Rudi H.
    Caballero, Joshua
    Sakharkar, Prashant
    Ahmed, Sultan
    Hurlston, Traci
    Parmar, Jayesh
    Deb, Subrata
    [J]. PLOS ONE, 2024, 19 (06):
  • [35] Cost Comparison for Glucose Testing by Point-of-Care Glucose Meter Compared With a Standard Laboratory Clinical Chemistry Analyzer: A Patient's Perspective From the Country of Thailand
    Wiwanitkit, Viroj
    [J]. POINT OF CARE, 2007, 6 (02): : 118 - 119
  • [36] POINT-OF-CARE AND STANDARD LABORATORY REFERENCE INTERVALS FOR COAGULATION VALUES IN ASIAN ELEPHANTS (ELEPHAS MAXIMUS): VARIATION BYAGE CLASS, SEX, AND TIME TO CENTRIFUGATION
    Ziegner, Kathryn E.
    Sadar, Miranda J.
    Brandao, Joao
    Rao, Sangeeta
    Ward, Erica
    Thepapichaikul, Wasinee
    DiGeronimo, Peter M.
    [J]. JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2022, 53 (02) : 291 - 301
  • [37] Comparison of Enterprise Point-of-Care and Nova Biomedical Critical Care Xpress analyzers for determination of arterial pH, blood gas, and electrolyte values in canine and equine blood
    Elmeshreghi, Taher N.
    Grubb, Tamara L.
    Greene, Stephen A.
    Ragle, Claude A.
    Wardrop, Jane A.
    [J]. VETERINARY CLINICAL PATHOLOGY, 2018, 47 (03) : 415 - 424
  • [38] Comparison of PT-INR Values Derived From Point-of-Care Devices Versus Coagulation Laboratory Instrument Results in a Multisite Anticoagulation Clinic
    Webster, Leeann K.
    Harrison, Harold
    Evans, Michael
    Forsythe, Melissa
    Amarose, Elizabeth
    Greskovic, Gerard
    Jones, Jay
    Rencavage, Karen
    Fitt, Walter
    Dorion, Patrick
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 2012, 87 : S156 - S157
  • [39] Concordance between point-of-care blood gas analysis and laboratory autoanalyzer in measurement of hemoglobin and electrolytes in critically ill patients
    Prakash, Shivesh
    Bihari, Shailesh
    Lim, Zhan Y.
    Verghese, Santosh
    Kulkarni, Hemant
    Bersten, Andrew D.
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (06)
  • [40] Comparing the accuracy of point-of-care with laboratory (capillary, venous, and arterial) blood glucose levels in critically ill patients with and without shock
    Abdulaziz Alshaer
    Basma A. Badgheish
    Zahra Hashim Alsadah
    Khalid Sewify
    Sarah Alghazal
    Sarah Alzahrani
    Abeer Qadi
    Reham Alqahtani
    Ghadeer Abdullah Farsani
    Amal Shilash
    [J]. BMC Research Notes, 15