Pure Interstitial Brachytherapy Using 3D-Printed Vaginal Template for Improved Catheter Tracks in Treating Cervical Cancer

被引:6
|
作者
Li, Jianping [1 ]
Meng, Xin [2 ]
Dang, Yunzhi [1 ]
Sun, Xiaohuan [1 ]
Zhang, Ying [1 ]
Wei, Lichun [1 ]
Shi, Mei [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Radiat Oncol, Xian 710032, Shaanxi, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, Xian 710032, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Personalized 3D Printing; Vaginal Template; Cervical Cancer; Intracavitary/Interstitial Brachytherapy; COMBINED INTRACAVITARY; CLINICAL FEASIBILITY; VIENNA APPLICATOR; MRI; RADIOTHERAPY;
D O I
10.1166/jbt.2017.1591
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cancer is the second ranked cause of death worldwide, which calls for the development of novel and effective therapies. However our current therapeutic options are mainly limited to chemo- and radio-therapy, surgery and other anti-cancer drugs, all of which suffer from either resistance or relapse of tumors. Cervical cancer is one of the most malignant cancers that preferably affect women. Recently, advanced techniques, such as Magnetic resonance imaging (MRI)-guided intracavitary/interstitial brachytherapies, have become increasingly important and promising in the diagnosis and treatment of cervical cancer. Hereby in our current report, we present two case studies of stage IVA cervical cancer, that utilized superior dose distribution by three dimension (3D) printing technology. We created digital 3D models for both patients, personalized to each of their individual anatomy with improved catheter tracks embedded in the template. We showed that the personalized 3D printed vaginal template has great potential in clinical treatment of cervical cancer.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 50 条
  • [31] AI-Assisted 3D Printing Transvaginal Template Guidance for Interstitial Brachytherapy in Patients with Cervical Cancer with Parametrial Invasion
    Li, H.
    Li, X.
    Zhang, J.
    Dai, Y.
    Lin, H.
    Xie, X.
    Yang, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E701 - E701
  • [32] Custom 3D-printed applicators for high dose-rate brachytherapy in skin cancer
    Membrive Conejo, Ismael
    Pera Cegarra, Oscar
    Foro Arnalot, Palmira
    Reig Castillejo, Ana
    Rodriguez de Dios, Nuria
    Sanz Latiesas, Xavier
    Pujol Vallverdu, Ramon M.
    Quera Jordana, Jaume
    Fernandez-Velilla Cepria, Enric
    Algara Munoz, Victor
    Algara Lopez, Manuel
    BRACHYTHERAPY, 2021, 20 (06) : 1257 - 1264
  • [33] Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery
    Huang, Huajun
    Hsieh, Ming-Fa
    Zhang, Guodong
    Ouyang, Hanbin
    Zeng, Canjun
    Yan, Bin
    Xu, Jing
    Yang, Yang
    Wu, Zhanglin
    Huang, Wenhua
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (01) : 109 - 117
  • [34] Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery
    Huajun Huang
    Ming-Fa Hsieh
    Guodong Zhang
    Hanbin Ouyang
    Canjun Zeng
    Bin Yan
    Jing Xu
    Yang Yang
    Zhanglin Wu
    Wenhua Huang
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 109 - 117
  • [35] Organ sparing treatment for penile cancer using a 3D-printed high-dose-rate brachytherapy applicator
    Lee, Hugh H. C.
    Chiu, Tsuicheng D.
    Hrycushko, Brian
    Xiong, Zhenyu
    Hudak, Steve
    Woldu, Solomon
    Mauck, Ryan
    Corwin, Terry
    Meng, Xiaosong
    Margulis, Vitaly
    Desai, Neil
    Folkert, Michael R.
    Garant, Aurelie
    BRACHYTHERAPY, 2023, 22 (05) : 580 - 585
  • [36] Development and promotion of a 3D-printed phantom model for ultrasound-guided caudal block followed by intracavitary/interstitial brachytherapy for gynecological cancer
    Kawamoto, Terufumi
    Oshima, Masaki
    Murakami, Naoya
    Okonogi, Noriyuki
    Muramoto, Yoichi
    Karino, Tatsuki
    Iijima, Kotaro
    Takatsu, Jun
    Inoue, Tatsuya
    Shikama, Naoto
    BRACHYTHERAPY, 2024, 23 (05) : 590 - 594
  • [37] 3D-Printed Template-Guided 125I Seed Brachytherapy: A Salvage Approach for Locoregional Refractory Recurrence of Papillary Thyroid Cancer
    Gao, Zhen
    Zhang, Hongtao
    Zhang, Lijuan
    Yu, Huimin
    Di, Xuemin
    Wang, Zeyang
    Liu, Zezhou
    Sui, Aixia
    Wang, Juan
    Shi, Gaofeng
    EUROPEAN THYROID JOURNAL, 2021, 10 (06) : 504 - 510
  • [38] Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom
    Kadoya, Noriyuki
    Miyasaka, Yuya
    Nakajima, Yujiro
    Kuroda, Yoshihiro
    Ito, Kengo
    Chiba, Mizuki
    Sato, Kiyokazu
    Dobashi, Suguru
    Yamamoto, Takaya
    Takahashi, Noriyoshi
    Kubozono, Masaki
    Takeda, Ken
    Jingu, Keiichi
    MEDICAL PHYSICS, 2017, 44 (04) : 1445 - 1455
  • [39] Toward 3D-TRUS image-guided interstitial brachytherapy for cervical cancer
    Knoth, Johannes
    Nesvacil, Nicole
    Sturdza, Alina
    Kronreif, Gernot
    Widder, Joachim
    Kirisits, Christian
    Schmid, Maximilian Paul
    BRACHYTHERAPY, 2022, 21 (02) : 186 - 192
  • [40] Deformable Image Registration Accuracy Between External Beam Radiotherapy and HDR Brachytherapy CT Images for Cervical Cancer Using a 3D-Printed Deformable Pelvis Phantom
    Miyasaka, Y.
    Kadoya, N.
    Kuroda, Y.
    Ito, K.
    Chiba, M.
    Nakajima, Y.
    Sato, K.
    Dobashi, S.
    Takeda, K.
    Jingu, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3736 - 3737