Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

被引:5
|
作者
Ahmed, Mohamed Attia Ali [1 ]
Abdelhalim, Ahmed Shawkat [1 ]
机构
[1] Menia Univ, Fac Med, Ophthalmol Dept, Al Minya, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
central corneal thickness; pachymeter; intraocular pressure; corneal thickness-corrected intraocular pressure; Goldmann applanation tonometry; anterior-segment optical coherence tomography; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; APPLANATION TONOMETRY; REPEATABILITY;
D O I
10.2147/OPTH.S288391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate variability in measured intraocular pressure (TOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools. Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35-76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT). Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected TOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively). Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.
引用
收藏
页码:4501 / 4506
页数:6
相关论文
共 50 条
  • [31] Methods of measuring intraocular pressure independently of central corneal thickness
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2008, 105 (09): : 840 - 844
  • [32] The intraocular pressure and central corneal thickness in healthy premature infants
    Acar, Damla Erginturk
    Acar, Ugur
    Tunay, Zuhal Ozen
    Ozdemir, Ozdemir
    Dolgun, Anil
    Erdurmus, Mesut
    JOURNAL OF AAPOS, 2015, 19 (02): : 108 - 111
  • [33] Central corneal thickness and measured intraocular pressure in diabetes.
    Kim, CY
    Kim, HK
    Lim, CS
    Oh, JH
    Hong, YJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S79 - S79
  • [34] New Non-contact Tonometer HNT-1P Reliability: Comparing Intraocular Pressure, Central Corneal Thickness, and Corrected Intraocular Pressure
    Eah, Kyu Sang
    Shin, Joong Won
    Sung, Kyung Rim
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (05): : 524 - 531
  • [35] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    Pensyl, D.
    Sullivan-Mee, M.
    Torres-Monte, M.
    Halverson, K.
    Qualls, C.
    EYE, 2012, 26 (10) : 1349 - 1356
  • [36] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    D Pensyl
    M Sullivan-Mee
    M Torres-Monte
    K Halverson
    C Qualls
    Eye, 2012, 26 : 1349 - 1356
  • [37] Intraocular pressure and central corneal thickness in full-term newborns
    Maestri Ferreira, Claudia Cardoso
    Tavares, Ivan Maynart
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (05) : 313 - 316
  • [38] Correlation Between Intraocular Pressure and Central Corneal Thickness in Persian Children
    Nejabat M.
    Heidary F.
    Talebnejad M.R.
    Salouti R.
    Nowroozzadeh M.H.
    Masoumpour M.
    Mahdaviazad H.
    Tajbakhsh Z.
    Keshtkar M.
    Jamali H.
    Khalili M.R.
    Movahedan H.
    Roustaei N.
    Gharebaghi R.
    Ophthalmology and Therapy, 2016, 5 (2) : 235 - 243
  • [39] Pediatric intraocular pressure measurements: Tonometers, central corneal thickness, and anesthesia
    Fayed, Mahmoud A.
    Chen, Teresa C.
    SURVEY OF OPHTHALMOLOGY, 2019, 64 (06) : 810 - 825
  • [40] Central Corneal Thickness and Intraocular Pressure in Women With Gestational Diabetes Mellitus
    Kan, Kok Wei
    Mohd, Mohd-Alif Wan
    Nik-Ahmad-Zuky, Nik Lah
    Shatriah, Ismail
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)