Correlation Between Intraocular Pressure and Central Corneal Thickness in Persian Children

被引:19
|
作者
Nejabat M. [1 ]
Heidary F. [1 ]
Talebnejad M.R. [1 ]
Salouti R. [1 ]
Nowroozzadeh M.H. [1 ]
Masoumpour M. [1 ]
Mahdaviazad H. [1 ]
Tajbakhsh Z. [1 ]
Keshtkar M. [1 ]
Jamali H. [1 ]
Khalili M.R. [1 ]
Movahedan H. [1 ]
Roustaei N. [2 ]
Gharebaghi R. [1 ]
机构
[1] Department of Ophthalmology, Poostchi Ophthalmology Research Center, Shiraz University of Medical Sciences, Shiraz
[2] Department of Biostatics, Faculty of Medicine, Shiraz University of Medical Sciences, Shiraz
关键词
Central corneal thickness; Intraocular pressure; Pediatric; Persian race;
D O I
10.1007/s40123-016-0063-5
中图分类号
学科分类号
摘要
Introduction: This study aimed to determine intraocular pressure (IOP) and central corneal thickness (CCT) measurements in healthy Persian children to find clinical reference values in this ethnicity. Additionally, we examined the possible relationship between these measurements. Methods: This cross-sectional study included 262 eyes of 131 Persian primary school children between 6 and 13 years of age. All eyes were healthy and had no anterior or posterior segment abnormalities, corneal disease, or evidence of glaucoma. Specular microscopy was used to measure CCT and both noncontact tonometry (NCT) and Goldmann applanation tonometer (GAT) were used to measure IOP. Correlations between IOP measurements were also examined. Results: Mean CCT was 513.47 ± 34.51 μm in the right eye (OD) and 513.93 ± 33.88 μm in the left eye (OS). The CCT was not significantly different between older (10–13 years) and younger (6–9 years) patients. Mean IOP measured with GAT was 13.86 ± 2.13 mmHg OD and 13.72 ± 2.04 mmHg OS and mean IOP measured with NCT was 15.26 ± 2.38 mmHg OD and 15.11 ± 2.18 mmHg OS. The IOP and CCT measured with GAT were weakly correlated (OD: r = 0.141, P = 0.114; OS: r = 0.236, P = 0.007). However, IOP and CCT measured with NCT (OD: r = 0.487, P = 0.000; OS: r = 0.456, P = 0.000) were moderately correlated. Our outcomes demonstrated that for 100 μm increase in CCT, IOP measured with GAT and NCT increased by 0.8 and 3.3 mmHg, respectively, in OD and by 1.4 and 2.9 mmHg in OS. Based on intraclass correlation coefficients, IOP measurements made with GAT and NCT were in fair agreement in OD and in good agreement in OS. Conclusion: The IOP and CCT in healthy Persian school children (6–13 years old) were positively correlated. Our findings revealed that corneal thickness is thinner in Persian children than in most other racial groups. Funding: This study has been funded by deputy dean in research of School of Medicine and deputy vice chancellor of Shiraz University of Medical Sciences, Shiraz, Iran. © 2016, The Author(s).
引用
收藏
页码:235 / 243
页数:8
相关论文
共 50 条
  • [1] The Correlation Between Central Corneal Thickness, Intraocular Pressure, Age and Gender
    Galgauskas, S.
    Garlaite, O.
    Juotkaite, G.
    Asoklis, R.
    Tutkuviene, J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] The correlation between the intraocular pressure, central corneal thickness, and signalment of the horse
    Zisopoulou, Aikaterini M.
    Vyhnalova, Natalia
    Janova, Eva
    Kolos, Filip
    Krisova, Sarka
    [J]. ACTA VETERINARIA BRNO, 2023, 92 (03) : 271 - 278
  • [3] Correlation between central corneal thickness and intraocular pressure in normal subjects
    Renucci, AM
    Romano, AC
    Yoo, SH
    Muallem, M
    Culbertson, WW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U377 - U377
  • [4] Correlation Between Central Corneal Thickness and Intraocular Pressure in Children; an Experience from Shiraz, Iran
    Heidary, Fatemeh
    Nejabat, Mahmood
    Gharebaghi, Reza
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Correlation between Central Corneal Thickness and Intraocular Pressure in Various Age Groups
    Marjanovic, Ivan
    Kontic, Djordje
    Hentova-Sencanic, Paraskeva
    Markovic, Vujica
    Bozic, Marija
    [J]. SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2010, 138 (5-6) : 279 - 286
  • [6] Central Corneal Thickness and Intraocular Pressure in Malay Children
    Heidary, Fatemah
    Gharebaghi, Reza
    Hitam, Wan Hazabbah Wan
    Naing, Nyi Nyi
    Wan-Arfah, Nadiah
    Shatriah, Ismail
    [J]. PLOS ONE, 2011, 6 (10):
  • [7] Correlation between the central corneal thickness and the daily Intraocular pressure in glaucomatous and suspected patients
    Cronemberger, S
    Calixto, N
    Torqueti, L
    Soares, FM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U672 - U672
  • [8] Positive correlation between Tono-Pen intraocular pressure and central corneal thickness
    Dohadwala, AA
    Munger, R
    Damji, KF
    [J]. OPHTHALMOLOGY, 1998, 105 (10) : 1849 - 1854
  • [9] Diurnal variations in intraocular pressure and central corneal thickness and the correlation between these factors in dogs
    Garzon-Ariza, Alicia
    Guisado, Alicia
    Galan, Alba
    Martin-Suarez, Eva
    [J]. VETERINARY OPHTHALMOLOGY, 2018, 21 (05) : 464 - 470
  • [10] Relationship between intraocular pressure, central corneal thickness and corneal topography
    Rinaldi, G
    Baccara, F
    Vattovani, O
    Gioulis, D
    Iacono, P
    Cecchini, P
    Ravalico, G
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U967 - U967