Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

被引:5
|
作者
Ahmed, Mohamed Attia Ali [1 ]
Abdelhalim, Ahmed Shawkat [1 ]
机构
[1] Menia Univ, Fac Med, Ophthalmol Dept, Al Minya, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
central corneal thickness; pachymeter; intraocular pressure; corneal thickness-corrected intraocular pressure; Goldmann applanation tonometry; anterior-segment optical coherence tomography; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; APPLANATION TONOMETRY; REPEATABILITY;
D O I
10.2147/OPTH.S288391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate variability in measured intraocular pressure (TOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools. Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35-76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT). Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected TOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively). Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.
引用
收藏
页码:4501 / 4506
页数:6
相关论文
共 50 条
  • [41] The correlation between the intraocular pressure, central corneal thickness, and signalment of the horse
    Zisopoulou, Aikaterini M.
    Vyhnalova, Natalia
    Janova, Eva
    Kolos, Filip
    Krisova, Sarka
    ACTA VETERINARIA BRNO, 2023, 92 (03) : 271 - 278
  • [42] Relationship of Central Corneal Thickness and Intraocular Pressure by iCare Rebound Tonometer
    Rao, Aparna
    Kumar, Mukesh
    Prakash, B.
    Varshney, Gopal
    JOURNAL OF GLAUCOMA, 2014, 23 (06) : 380 - 384
  • [43] Falsely elevated intraocular pressure due to increased central corneal thickness
    Bron, AM
    Creuzot-Garcher, C
    Goudeau-Boutillon, S
    d'Athis, P
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (03) : 220 - 224
  • [44] Diurnal variation of central corneal thickness and intraocular pressure in eyes with pseudoexfoliation
    Syed, Zeeshan
    Srikanth, Krishnagopal
    Nagarajan, Swathi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1607 - 1609
  • [45] Normative data for intraocular pressure and central corneal thickness in preterm infants
    Khaja, Wassia
    Chalam, Kakarla V.
    Grover, Sandeep
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [46] Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma
    Fogagnolo, P
    Rossetti, L
    Mazzolani, F
    Orzalesi, N
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (01) : 24 - 28
  • [47] Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure
    Manassakorn, Anita
    Chaidaroon, Winai
    ASIAN BIOMEDICINE, 2012, 6 (02) : 291 - 296
  • [48] The Correlation Between Central Corneal Thickness, Intraocular Pressure, Age and Gender
    Galgauskas, S.
    Garlaite, O.
    Juotkaite, G.
    Asoklis, R.
    Tutkuviene, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [49] Relation between central corneal thickness and intraocular pressure in Punjabi population
    Kohli P.G.
    Randhawa B.K.
    Singh K.D.
    Randhawa G.S.
    Kohli A.K.
    Journal of Medical Engineering and Technology, 2010, 34 (01): : 1 - 6
  • [50] Falsely elevated intraocular pressure due to increased central corneal thickness
    Alain M. Bron
    Catherine Creuzot-Garcher
    Sophie Goudeau-Boutillon
    Philippe d’Athis
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1999, 237 : 220 - 224